4.4- Mode
There are several modes for each output. Filtration and chlorinator related, while lights is
completely independent.
Filtration:
-
Manual OFF: The pump will remain permanently off.
-
Manual ON: The pump will remain permanently on.
-
Automatic: The pump will follow the established hourly schedule.
-
Remote: The pump will turn on upon receiving the signal from the chlorinator
other external programmer that acts on the remote input)
section 3.3 of the installation in remote mode.
Chlorinator:
-
Manual OFF: The chlorinator will remain permanently off.
-
Automatic: The chlorinator will turn on whenever the pump does.
-
Automatic TMR: The chlorinator will turn on for the specified time, whenever the pump
does. This timer will restart again for the next filtration cycle.
Lights:
-
Manual OFF: The lights will remain permanently off.
-
Manual ON: The lights will remain permanently on.
-
Manual TMR: The lights will remain on for the specified time.
-
Automatic: The lights will follow the established hourly schedule.
Fig. 13: Selection of the operating Mode.
(or any
. Please review carefully
34