Item:
OS-PIR-UNV
INSTALLATION INSTRUCTIONS
Motion Sensor Parameter Setting:
Note: Factory default settings are as follows: 100%
brightness 100% sensitivity, 1 minute hold
time, disabled daylight sensor, 30% stand-by
level and 0 seconds stand-by time.
HOLD
DAYLIGHT: 5, 6
www.topaz-usa.com | 800.666.2852 | ©2022 Southwire Company, LLC. All rights reserved.
OCCUPANCY SENSOR
1. Remove the lens cover by twisting counterclockwise 90° and gently
liftng off the lens cover. You will find switches to set the parameters
for the environment.
Switches 1&2 control Sensitivity.
•
Switches 3&4 control Hold Time.
•
•
Switches 5&6 control the Daylight threshold.
Switches 7&8 control Stand-by Light Level.
•
Switches 9&10 control Stand-by Time.
•
2. Switches 1 and 2 control the sensitivity. This setting controls the
detection range. Follow the diagram to set the sensitivity needed for
the environment
3. Switches 3 and 4 control the Hold Time. This setting controls how
long the fixture will stay illuminated after sensing motion. Follow the
diagram to set the Hold Time.
4. Switches 5 and 6 control the Daylight threshold. This setting controls
the maximum amount of daylight that will allow the fixture to
illuminate. Follow the diagram to set the Daylight threshold.
5. Switches 7 and 8 control the Stand-By Level. This setting controls the
amount of light that will remain after the Hold Time has expired.
Follow the diagram to set the Stand-By Level.
6. Switches 9 and 10 control the Stand-By Time. This setting controls
the amount of time the fixture will stay on at the Stand-By Level.
Follow the diagram to set the Stand-By Time.
7. Once the Parameters are set, install the sensor into the fixture. Close
the fixture and turn on power.