8.
Spare parts
Order original spare parts from the Hoffmann Group Customer Service.
9.
Recycling and disposal
Do not dispose of the endoscope probe in domestic waste.
Comply with the national regulations for disposal. Users have an obligation
to take the endoscope probe to a suitable collection point.
10. Technical data
Data
Weight
Dimensions
Length of camera head
Material of camera head
Hose length (without tip)
Hose diameter
Sensor resolution
LED
Depth of focus
Field of view
Operating temperature
Index of protection
Video output format
Joint angle
Joint radius
Image rate
Length 1500
395 g
176 × 35 × 52 mm
13 mm
Stainless steel
1500 mm
4.5 mm
VGA (640×480)
White LED. To the front: 360 mcd * 5 LED
1–10 cm
90 degrees (diagonally)
0°C–60°C
IP 67
NTSC
Two sides, left 180°/right 180°
40 mm ± 5 mm
30 fps
Length 3000
430 g
3000 mm