3.TYPES OF CODES
For security reasons, it is important to change the initial
codes and set new ones..
3.1. MASTER CODE
8 digits, initial code 20050330..
Functions:
• Allows you to set, change and delete master and user
codes.
• Allows you to open and close the lock..
3.2. USER CODE
4 digits, initial code 1111.
Functions:
• Allows you to change the user code.
• Allows you to open and close the lock.
4. OPENING
Enter the opening code, turn the knob anticlockwise and
lift the parcel box lid. You have 3 seconds to open the lock.
For the first opening, use the initial codes (user: 1111 or
master: 20050330).
If the code is entered incorrectly 5 times consecutively, the
lock will automatically be blocked for 5 minutes.
5. EMERGENCY OPENING
Remove the protective cover from the knob to access the
lock (we recommend the use of a magnet to remove the lid
more easily), insert the master key and turn it clockwise.
Note: Emergency opening does not erase configured codes.
6. CLOSING
Lower the parcel box lid and turn the knob clockwise.
7. SETTING AND CHANGING CODES
7.1. CHANGING THE USER CODE
a. If the USER performs the operation:
Enter
--user code--#--new 4-digit user code--#
*
b. If the MASTER performs the operation:
Enter
--master code--#--02--#--new 4-digit user code--#
*
7.2. CHANGING THE MASTER CODE
Enter
--master code--#--01--new 8-digit master code--#--
*
repeat new master code--#
7.3. DELETING CODES
Only the MASTER is authorised to delete the user code.
To delete the user code, enter
After deleting the user code, the initial code 1111 is
reactivated.
19
--master code--#--03--#
*
En