Descargar Imprimir esta página

PNI CT440 Manual Del Usuario página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
Temperature control from the thermostat
Press the Up and Down keys on the central unit to set the desired
temperature.
Heating mode:
If the set temperature (SET) is higher than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The Zone
LED on the receiver unit will light up and a click will be heard
indicating the activation of the internal relay. The icon
(the heating system is on) appears on the screen of the
central unit.
If the set temperature (SET) is lower than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The Zone
LED on the receiver unit will go out and a click will be heard
indicating the activation of the internal relay. The icon
disappears from the screen.
Cooling mode:
If the set temperature (SET) is lower than the temperature
in the room (ROOM), the central unit will send a command
to the receiver unit in a maximum of 90 seconds. The Zone
LED on the receiver unit will light up and a click will be heard
User manual