General Descriptions; Technical Specifications - Ratio INV130 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTROMAGNETIC DISTURBANCES
Electromagnetic interferences produced by welding equipment may interfere in the operation of equipment
which is sensitive to this kind of interference (computers, robots etc). Ensure that all the equipment in the
welding area is resistant to electromagnetic radiation. In order to reduce radiation as much as possible, work
with welding wires as short as possible and placed in parallel on the floor if possible. Work at a distance of
100 meters or more from equipment which is sensitive to disturbances. Ensure that the machine equipment
is correctly earthed. If there are still interference problems despite having taken the above described
precautionary measures, the operator must take extra measures such as moving the welding machine, using
filters or protected cables to ensure that interference with other equipment does not occur.
RECYCLING
In compliance with European Directive 2002/96/EC on waste electric and electronic equipment, this
equipment must be deposited in your local recycling centre at the end of its useful life.

GENERAL DESCRIPTIONS

MEANING OF THE INDICATIONS ON THE SPECIFICATIONS PLATE
EN 60974
S/N ...
MMA
Uo
X
I1 max.
I1 eff.
I2
U2
U1
X ph
50/60 Hz
IP XX

TECHNICAL SPECIFICATIONS

Input voltage (U1)
Maximum input current (I1 max)
MMA-TIG Duty cycle (40ºC) 35%
MMA-TIG Duty cycle (40ºC) 100%
No-load voltage (U0)
Max. absorbed power
Temperature protection class
IP protection class
EMC class
Weight (Kg)
Dimensions (mm)
Standards
The machine is designed to be used outdoors. However, it should be protected from rainfall while it's in use.
International Standard for welding equipment
Serial number
MMA welding
No-load welding voltage.
Duty Cycle %.
Max. instantaneous absorbed current.
Max. effective absorbed current
Welding current (A).
Test voltage for welding current (I2).
Supplying voltage.
Number of phases to be connected
Frequency.
IP protection class.
INV130
230V (220~240)
50/60Hz
22A
130A
47A
68V
5,06
H (180º)
IP21S
315x102x176
EN60974-1
INV160
230V
(220~240)
50/60Hz
30A
160A
115A
68V
6,9
H (180º)
IP21S
F
F
3
3,1
315x102x176
EN 60974-1
INV200
230V
(220~240)
50/60Hz
40A
200A (40%)
135A
72V
9
H (180º)
IP21S
F
5.5
370x120x210
EN 60974-1
10

Publicidad

Tabla de contenido
loading

Productos relacionados para Ratio INV130

Este manual también es adecuado para:

Inv160Inv200

Tabla de contenido