FEATURES
KNOW YOUR TOOL
Before attempting to use this product, become
familiar with all of its operating features and
safety requirements.
5
1. TERMINAL COVER.
2. WATER INLET.
3. WATER OUTLET.
4. PRIMER VALVE.
5. FAN COVER.
6. IMPELLER CASING.
TECHNICAL DATA
BP505
VOLTAGE-FREQUENCY
CURRENT
INLET-OUTLET
POWER
NO LOAD SPEED
MAX. FLOW
MAX HEIGHT (Hmax)
MAX TEMPERATURE OF WATER
WATER PROTECTION
WORK CYCLE
DAILY MAXIMUM USE
POWER CONSUMPTION
WEIGHT
BP575
VOLTAGE-FREQUENCY
CURRENT
INLET-OUTLET
POWER
NO LOAD SPEED
MAX. FLOW
MAX HEIGHT (Hmax)
MAX TEMPERATURE OF WATER
WATER PROTECTION
WORK CYCLE
DAILY MAXIMUM USE
POWER CONSUMPTION
WEIGHT
12
1
3
4
2
6
127 V ~ 60 Hz
5,3 A
1"/1" NPT
1/2 HP (373 W)
3450 rpm
38 L/min
43 m
35º C
IPX4
40 min / 20 min
6 horas
0,4 kWh
5,5 kg (12,1 lb)
127 V ~ 60 Hz
10,5 A
1"/1" NPT
3/4 HP (550 W)
3450 rpm
50 L/min
60 m
35º C
IPX4
40 min / 20 min
6 horas
0,6 kWh
8,5 kg (18,7 lb)
BP510
VOLTAGE-FREQUENCY
CURRENT
INLET-OUTLET
POWER
NO LOAD SPEED
MAX. FLOW
MAX HEIGHT (Hmax)
MAX TEMPERATURE OF WATER
WATER PROTECTION
WORK CYCLE
DAILY MAXIMUM USE
POWER CONSUMPTION
WEIGHT
OPERATION INSTRUCTIONS
This pump is designed to suck water at a height
of up to 8 meters at sea level, this condition de-
creases as the height of the city or workplace
increases.
- For best results, install your water pump as
close as possible to the water mirror, the water
mirror should be at least 20 inches above the
foot valve. Calculate correctly the demand of
your system and the correct diameter of the
pipes.
- If your motor pump is going to be set at a fixed
place, attach it firmly to the floor (use clamps,
expansive raw plugs, etc.)
always sure that it will not be moving for the
vibration.
The pump should
be installed in
a dry, properly
ventilated loca-
tion at an ambi-
ent temperature
not to exceed 40
° C (104 ° F).
NEVER ALLOW THAT YOUR MOTOR GETS
WET, USE PROTECTION COVER IF OUTDOORS.
AVOID COVERING THE MOTOR OF YOUR
MOTOR PUMP WITH PLASTIC THAT PREVENT
THE CIRCULATION OF AIR THROUGH IT SO THAT
IT COOLS DOWN. PLACE YOUR MOTOR PUMP
AT A VENTILATED PLACE.
127 V ~ 60 Hz
11,5 A
1"/1" NPT
1 HP (745 W)
3450 rpm
60 L/min
65 m
35º C
IPX4
40 min / 20 min
6 horas
0,7 kWh
8,7 kg (19,2 lb)
Otherwise, make