Set-Up Instructions
Select the application mode. See Chapter 9 for the application description.
Press (M) until F100 is shown on the display
Press (O) until only the FWD LED is illuminated (X O X X)
Press (UP) to access parameter block F2xx
Press (O) until both the FWD and DGT LEDs are illuminated (X O O X)
Press (UP) until display shows F228
Press (E) to edit the application number
Use the (UP) and (DOWN) keys to select the application
Press (E) to confirm your selection
Application is set as default, this allows access to all paramaters please see the full manual for
description on all operations.
For application connection drawings please see the end of this quick start guide.
Set the Motor Paramaters
F801 Rated power (kW)
F802 Rated voltage (V)
F803 Rated current (A)
F804 Number of motor poles Setting range: 2~100
F805 Rated rotary speed
F810 Motor rated frequency
Select control mode
The AC10 inverter has three control modes: sensorless vector control (F106=0), VVVF control (F106=2)
and vector control 1 (F106=3). Under VVVF control mode, theAC10 inverter has four kinds of torque
compensation modes: Linear compensation (F137=0); Square compensation (F137=1); User-defined
multipoint compensation (F137=2); Auto torque compensation (F137=3)
Set the limits
F111 Max Frequency (Hz)
F112 Min Frequency (Hz)
Set the ramp rates
F114 First Acceleration Time (S)
F115 First Deceleration Time (S)
F116 Second Acceleration Time (S)
F117 Second Deceleration Time (S)
Set the I/O control mode
The channel for inverter to receive control commands (including start, stop and jogging, etc) contains 5
modes: 0. Keypad control; 1. Terminal control; 2. Keypad + terminal control 3. Modbus control; 4. Keypad
+ terminal +Modbus. The modes of control command can be selected through the function codes F200
and F201.
F200
F201
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com
Application selection
F228
Setting range: 0.75~1000
Setting range: 1~440
Setting range: 0.1~6500
Setting range: 1~30000
Setting range: 1.0~590.0
Setting range: F113~590.0
Setting range: 0.00~F113
Source of start command
Source of stop command
0: Invalid
1: Basic speed control
2: Auto/manual control
3: Stage speed control
4: Terminal control;
5: PID control;
Mfr's value: 50.00
Mfr's value: 0.50
Mfr's value: subject to
Setting range:
inverter model
0.1~3000
0: Keypad command;
1: Terminal command;
2: Keypad+Terminal;
3: MODBUS;
4: Keypad+Terminal+MODBUS
0: Keypad command;
1: Terminal command;
2: Keypad+Terminal;
3: MODBUS;
4: Keypad+Terminal+MODBUS
4
50.00
1-8