ENERMAX Platimax Series Power Supply Specification
AC Input Voltage
AC Input Current
3.3V
5V
12V1
12V2
12V3
12V4
12V5
12V6
-12V
5Vsb
Total Power
Peak Power*
Over Current Protection
(DC)
Under Voltage / Over
Voltage Protection
(AC)
Under Voltage Protection
Over Power Protection
Over Temperature
Protection
Short Circuit Protection
Temperature
Humidity
MTBF
Dimension
Weight
Safety
EMC
* Peak power may last up to 60 seconds.
EPM1050EWT
(Maximum range: 90-264VAC, 47-63Hz)
12-5A
DC Output
Rated
Combined
0-24A
0-24A
0-30A
0-30A
0-30A
0-30A
0-30A
0-30A
0-0.5A
0-3A
1050W
1260W
Protection Circuit
DC Rail
3.3V
5V
12V1/2/3/4/5/6
DC Rail
3.3V
5V
12V1/2/3/4/5/6
-12V
+5Vsb
Activated when AC input voltage < 70VAC.
Activated when output power > 110 ~160% of rated max load.
Activated when PSU heat sink > 90 ~ 110
Activated when any DC rails short-circuited.
ENVIRONMENT
Operation ambient: 0~40
Storage ambient: -40~70
Operation: to 85% relative humidity, non-condensing at 25
Storage: to 95% relative humidity, non-condensing at 50
OTHERS
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
(MIL-HDBK-217F standard)
150 (w) x 86 (h) x 180 (d) mm
2.25kg (without modular cables) ±50g
UL/cUL(Level 6), TUV, GOST, CB, BSMI
CE, FCC, KCC
2
EPM1200EWT
100-240VAC, 50-60Hz
Rated
0-24A
120W
0-24A
0-30A
0-30A
0-30A
1044W
(87A)
0-30A
0-30A
0-30A
6W
0-0.5A
15W
0-3A
OCP trigger range
UVP trigger
range
2.0 – 2.4V
3.3 – 3.7V
8.5 – 9.5V
-9.5 – -10.5V
o
C.
o
C
o
C
14-5.5A
Combined
120W
1200W
(100A)
6W
15W
1200W
1440W
30 – 45A
30 – 45A
40 – 50A
OVP trigger
range
3.9 – 4.5V
5.7 – 6.5V
13.3 – 14.5V
5.6-6.5V
o
C
o
C
o
C