Separate the front housing of thermostat from wall module:
1.
Unscrew both closing screws (bottom of stat) until they will not turn any further.
2.
Release front housing by gripping lower half of outer frame and pulling outwards then upwards
3.
Place front housing somewhere safe
4.
Run all wires to the wall box. Check to ensure that you have included the following:
Power (Live and Neutral)
Heater (Live and Neutral or Switch Live only)
Floor sensor
Fil pilote (if necessary)
External/ 2nd floor Sensor (if necessary)
5.
Pull wires through wall box and complete terminal wiring.
IMPORTANT: Ensure that multi stranded wires are fully inserted into the terminals and secured tightly. Any loose strands should be trimmed as they could cause a short-circuit.
If connecting more than two heaters, an electrical junction box will be required.
NOTE: Always ensure that the sensor cable is installed in a separate
conduit to the power cables supplying the thermostat and heating system.