Additional Information; Maintenance - Sony PS-LX300H1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Additional Information

Maintenance

Stylus and Record Care
In order to prevent premature stylus and record wear,
the stylus and record should be cleaned before
playback.
To clean the stylus, brush it from back to front using a
good quality stylus cleaning brush. Do not clean the
stylus with your finger tip. When using a fluid stylus
cleaner, make sure not to moisten the stylus too much.
To clean your records, wipe thoroughly using a good
quality record cleaner.
Cleaning the Shell Terminals
If you notice a drop in sound quality, excessive noise,
or hum, this may be a result of incomplete contact due
dust or dirt on the shell terminals. Remove the shell
from the tone arm and wipe the terminals lightly with
a soft cloth, and reattach the shell to the tone arm.
Cleaning the Cabinet and Dust Cover
Clean the cabinet and dust cover periodically using a
soft dry cloth. If stains are difficult to remove, use a
cloth moistened with a mild detergent solution. Do not
use solvents such as alcohol, benzine or thinner, since
they will damage the finish.
Replacing the Stylus
The life expectancy of the stylus tip is about 500 hours.
To preserve maximum sound quality and avoid
damage to your records, we recommend replacing the
stylus within this time limit.
Additional replacement styli (CN-251) are available
from your Sony dealer.
To replace the stylus
1
2
3
4
Replacing the Cartridge
If you find it necessary to replace the cartridge detach
the headshell from the tone arm and follow the
directions below.
1
2
Shell terminals
3
Turn off the turntable and amplifier.
Turn the locking collar and remove the cartridge
from the tone arm.
Grasp the stylus holder and pull it away from the
body of the cartridge.
Insert the new stylus by pushing it into the
cartridge receptacle.
Remove the screws holding the cartridge to the
headshell.
Detach the four lead wires from the cartridge by
pulling on the lead terminals with a small pair of
pliers (etc.).
The cartridge should now be completely detached
from the headshell.
Check the location and polarity of each of the
terminal pins on the new cartridge and connect
the lead wires accordingly.
The terminal polarity of the lead wires on the
accessory headshell are shown below.
Red:
Right channel
White:
Left channel
Green:
Right channel earth
Blue:
Left channel earth
Be careful not to mix the polarities.
7
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido