TEST FOR WIND-SENSOR TYPE WINDTEC-SC
This function is useful to check the correct connection to the control unit and the rotation
direction in case of wind-alarm. Activate the TEST function, with the sequence B+C, C.
The awning opens for 10 seconds and closes briefly to confirm that the test mode is
activated. Move the anemometer blades by hand, the motor performs short moves in
closing direction. If the direction is not right it's necessary to invert the rotation direction.
To quit the test mode press any button from the remote control. During the wind-alarm the
red led inside the control unit is on.
B
+ C
C
GB
30