SWITCH
It is possible to drive the motor through a switch connected to the control unit with
three wires (up, down, common), momentary single pole, double throw (centre-off)
switch with mechanical or electrical interlocking to prevent connection to both terminals
simultaneously.
FUNCTIONING
Pressing one of the two buttons and releasing, the motor drives to the desired direction
until it reaches the limits. To stop the motor before reaching the limits press again the
same button. If during the movement the other button is pressed the motor changes the
direction.