Access To Menus - BFT LEO-MA UL Instrucciones De Uso Y De Instalacion

Uadro de mandos para operador icaro-c
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ACCESS TO MENUS

Press the OK key
OK
BFT
Display software version
Disp 1. 0
Control unit software version
LEO-ma 1. 0
OK
No. total manoeuvres
0000
(in thousands)
0000
No. manoeuvres since latest
maintenance(in thousands)
00
No. radio control devices
memorised
PARAM.
+/-
- +
+/-
LOGIC.
+/-
- +
FOLLOWING MENUS
FIG. B
00
[
]
/ON
/OFF
OK
- +
+/-
Part. Open
OK
- +
TCA
- +
ENCOder
- +
open torque
- +
cls torque
- +
Slovd tor
- +
brake
- +
ZONE
- +
dist slov
TCA
OK
OK
- +
3 step
OK
- +
iblopen
OK
- +
ibl
tca
OK
- +
PRE-ALarm
OK
- +
hold-to-run
OK
- +
fast cls
OK
- +
photoc. open
OK
- +
Master
OK
- +
LOOP
OK
- +
test phot
OK
- +
test bar
OK
Fig. A
8888
OK
Preset value
Parameter increment/reduction
or ON/OFF commutation
Press OK key (Enter/confirm)
Menu scrolling
(+ = preceding - = following)
[010]
OK
[040]
OK
[080]
OK
[050]
OK
[050]
OK
[050]
OK
[000]
OK
[000]
OK
[000]
OK
ON
[oFF]
OFF
ON
[off]
OFF
ON
[oN]
OFF
ON
[off]
OFF
ON
[off]
OFF
ON
[off]
OFF
ON
[off]
OFF
ON
[oN]
OFF
ON
[off]
OFF
ON
[off]
OFF
ON
[off]
OFF
ON
[off]
OFF
LEGENDA
+/-
Simultaneously press the + and - keys.
Simultaneous pressure of the + and – keys
allows you to exit the active menu and return
to the preceding menu; if this takes place at
the main menu level, programming is exited
and the display switched off.
The modifications made are only confirmed if
the OK key is subsequently pressed.
PRG
OK! message (confirms modification made)
PRG
KO! message (value or function error)
"Wait" message (enter value or function)
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PARAMETER MENU
PRG
OK
Partial opening - value expressed in %
(default 010%, min 000%, max 100%)
PRG
OK
TCA - value expressed in seconds (default
40=40s, min 1=1s, max 180=180s)
Encoder – value expressed in % (default
PRG
80%, min 1%, max 99%)
OK
Opening torque – value expressed in %
(default 50%, min 1%, max 99%)
PRG
Closing torque – value expressed in %
OK
(default 50%, min 0%, max 99%)
Slow-down torque – value expressed in %
(default 50%, min 1%, max 99%)
PRG
OK
Brake – value expressed in % (default 0%,
min 1%, max 99%)
Zone – numerical value (default 0, min 0,
PRG
OK
max 127)
Slow-down distance value expressed in %
(default 000%, min 20%, max 100%)
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
PRG
OK
15
LEO-MA UL - Ver. 01 -

Publicidad

Tabla de contenido
loading

Tabla de contenido