Access To Menus; Parameter Menu - BFT URANO BT Instrucciones De Uso Y De Instalacion

Servomotor para cancelas correderas de cremallera
Ocultar thumbs Ver también para URANO BT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39

ACCESS TO MENUS

Press the OK key
OK
bFt
Control unit software version
qscd urano
OK
No. total manoeuvres
0000
(in hundreds)
0000
No. manoeuvres since latest
00
maintenance (in hundreds)
No. radio control devices
memorised
PArAM
+/-
FINE
- +
LoGIc
+/-
FINE
- +
FOLLOWING MENUS
FIG. B
888 8
[ 00 ]
Preset value
Parameter increment/reduction
/ON
/OFF
or ON/OFF commutation
Press OK key (Enter/confirm)
OK
- +
Menu scrolling
(+ = preceding - = following)
+ -
OK
tcA
- +
OP. T
- +
CLS. T
- +
op. t slow
- +
cls. t slow
- +
norm. op. speed
- +
norm. cls. speed
- +
slow speed
- +
Zone
+ -
OK
tcA
- +
3 step
- +
ibl open
- +
photoc. open
- +
tEst Phot
- +
ScA 2ch
- +
preal
- +
hold-to-run
- +
START-CLOSE
- +
fixed code
- +
radio prog
- +
MAStEr
Fig. A
+
OK
[ 010]
OK
[ 080]
OK
[ 080]
OK
[ 025]
OK
[ 025]
OK
[ 15. 0 ]
OK
[ 15. 0 ]
OK
[ 1
]
OK
[ 0
]
OK
[oFF]
ON
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
LEGENDA
+ -
Simultaneously press the + and - keys.
Simultaneous pressure of the + and – keys
allows you to exit the active menu and return
to the preceding menu; if this takes place at
the main menu level, programming is exited
and the display switched off.
The modifications made are only confirmed if
the OK key is subsequently pressed.
PrG
Message: Programming in progress
KO! message (value or function error)
"Wait" message (enter value or function)
OK
PrG
PrG
OK
OK
PrG
OK
PrG
OK
PrG
PrG
OK
OK
PrG
OK
PrG
OK
PrG

PARAMETER MENU

OK
PrG
TCA (automatic closing time)
value expressed in seconds
PrG
OK
(default 10=10s, min 3=3s, max
120=120s)
Opening Motor torque – value
expressed in % (default 80%, min 1%,
OK
PrG
max 99%)
Closing Motor torque – value
expressed in % (default 80%, min 1%,
OK
PrG
max 99%)
Slow-down opening motor torque –
value expressed in % (default 25%,
min 1%, max 99%)
PrG
OK
Slow-down closing motor torque –
value expressed in % (default 25%,
min 1%, max 99%)
Fast opening time
PrG
OK
value expressed in seconds
(default 25=25s, min 1=1s, max 2=2 min)
Fast closing time
PrG
OK
value expressed in seconds
(default 25=25s, min 1=1s, max 2=2 min)
Slow-down numerical value
(default 1, min 1, max 3)
OK
PrG
Zone numerical value
(default min 0, max 127)
OK
PrG
PrG
OK
PrG
OK
OK
PrG
21
URANO BT Ver. 04 -

Publicidad

Tabla de contenido
loading

Tabla de contenido