Textron GREENLINE CM-700 Manual De Instrucciones página 12

Medidores digitales con pinza
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy
See the Specifications section for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at
• 18 °C to 28 °C (64 °F to 82 °F) for voltage and resistance measurements
• 21 °C to 26 °C (70 °F to 79 °F) for current measurements
• 0% to 80% relative humidity
AC Current (21 °C to 26 °C) for CM-700*
Range
400.0 A
200.0 to 400.0
600 A
AC Current (21 °C to 26 °C) for CM-750**
Range
400.0 A
200.0 to 400.0
600 A
AC Voltage (18 °C to 28 °C) for CM-700* and CM-750**
Range
400.0 mV
± (1.5% + 0.005 V)
4.000 V
± (1.5% + 0.05 V)
40.00 V
± (1.5% + 0.5 V)
400.0 V
± (1.5% + 5 V)
600 V
* CM-700 is average sensing, RMS calibrated.
** CM-750 is true RMS sensing. Accuracy is specified for sine waves at full scale and non-sine
waves below half scale. For non-sine waves, add the following crest factor corrections:
• Crest factor 1.4 to 2.0, add 1.0%
• Crest factor 2.0 to 2.5, add 2.5%
• Crest factor 2.5 to 3.0, add 4.0%
12
Input Value
0.0 to 40.0
40.0 to 200.0
400 to 600
Input Value
0.0 to 40.0
40.0 to 200.0
400 to 600
Accuracy
Unspecified
Accuracy (50 to 60 Hz)
± (1.9% + 0.7 A)
± (1.9% + 0.5 A)
± (3.0% + 0.5 A)
± (1.9% + 10 A)
Accuracy (50 to 60 Hz)
± (1.9% + 0.7 A)
± (1.9% + 0.5 A)
± (3.5% + 0.5 A)
± (1.9% + 10 A)
Frequency Response
Unspecified
40 to 300 Hz
40 to 500 Hz
Accuracy (60 to 400 Hz)
± (2.5% + 0.7 A)
± (2.5% + 0.5 A)
± (3.6% + 0.5 A)
± (2.5% + 10 A)
Accuracy (60 to 400 Hz)
± (2.5% + 0.7 A)
± (2.5% + 0.5 A)
± (3.6% + 0.5 A)
± (2.5% + 10 A)
Input Impedance
9 MΩ, 100 pF