Thanks to its antibacterial, antimicrobial, immunomodulating and anti-inflammatory
properties, ozone is able to rapidly decompose bacteria and viruses, preventing inflammatory
processes and promoting healing at the cellular level.
Aquolab's jet of water and ozone eliminates bacteria and viruses from the patient's mouth
gently, painlessly and in just a few seconds, without leaving any chemical residue, because
the ozone transforms into oxygen after a few seconds. Aquolab produces ozone internally,
in predetermined amounts, in full compliance with European safety standards (TLV STEL and
TLV TWA), with no need for external oxygen tanks. The ozone mixed with water is particularly
effective and, moreover, it is not released into the air, and therefore cannot be inhaled by the
patient, a fact which makes this device even safer. Aquolab can operate effectively using regular
potable water, but it can also be used with distilled water or with a physiological solution.
The protocols for use list the water and ozone levels, for easy, safe and fast treatments of a
wide range of case types.

FIELDS OF APPLICATION:

Non-surgical periodontal therapy
Support (disinfection pre- and post-surgery) for oral surgery, mucogingival surgery,
implant surgery
Support (disinfection) for root canal therapy
Professional oral hygiene (pre- and post-treatment)
Oral hygiene treatments for patients with implants and prostheses
Oral hygiene treatments for patients undergoing orthodontic treatments
Peri-implantitis treatment
Treatment of candidiasis and stomatitis
Any other use than the intended one constitutes an improper use. Therefore, the manufacturer
cannot be held liable for any damage caused by an improper, incorrect and/or unreasonable use or
if the device is connected to electrical installations which do not comply with safety regulations in
force.
The Aquolab dental water jet is not suitable for use in pure oxygen-rich spaces or where there
are flammable anaesthetic mixtures.
GENERAL RULES FOR THE CORRECT USE OF THE AQUOLAB DEVICE
The protocols for using Aquolab are subject to continuous updating and revision.
Visit www.aquolab.com/professionisti to download the latest version or request a copy at
info@aquolab.com
ACTIVATION
You must read the instruction manual and safety rules carefully before use.
Place Aquolab on a horizontal surface.
Connect the handle (tube) to the Device.
Connect the power supply charger to an easily accessible outlet.
Connect to an electrical system constructed in accordance with the safety standards.
Now your Aquolab Professional is ready.