Orbis CODITEL 2 Manual Del Usuario página 42

Interfaz de comunicación gsm
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OUTRING [output number][output status][status holding time][unit of measurement],
where
− [output number] 
− [output status] 
− [status holding time] 
− [unit of measurement]  s seconds, m minutes, h hours (optional parameter)
Some examples:
OUTRING 1 ON
OUTRING 1 OFF 10 S
OUTRING 2 DISABLE
OUTRING 2 TOGGLE
• Setting the output status
To send more complex commands to the instrument, text messages must be used.
The possible commands are:
OUT [output number][output status][status holding time][unit of measurement], where
− [output number] 
− [output status] 
− [status holding time] 
− [unit of measurement]  s seconds, m minutes, h hours (optional parameter)
Some examples:
OUT 1 OFF 10 S
OUT 2 ON 12 H
• Setting the text message forwarding to the sender (for admin only)
The instrument can be set to send the sender a text message of confirmation upon
receiving a command via a text message. The command is
OUTRISP [status] with status that can assume the values:
− ON  enables the sending of a text message of reply to the sender
− OFF  disables the sending of a text message of reply to the sender
indicates the output to which reference is made (1 or 2)
can assume the values ON, OFF, TOGGLE, DISABLE
maximum time setting (2
opzionale)
the relay 1 is turned ON
the relay 1 is turned OFF for 10 seconds when the ring is
received
the relay 2 does not do anything when the ring is received
the relay 2 changes position when the ring is received
indicates the output to which reference is made (1 or 2)
can assume the values ON, OFF
maximum time setting (2
parameter)
sets the relay 1 OFF for 10 seconds
sets the relay 2 ON for 12 hours
- 40 -
User Manual CODITEL 2
-1) secondi (parametro
32
-1) seconds (optional
32

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Orbis CODITEL 2

Tabla de contenido