Bissell 2215 SERIE Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Replace Brush & Belt
WARNING
To reduce the risk of electrical shock, turn power switch off and disconnect polarized plug
from electrical outlet before performing maintenance or troubleshooting checks.
1
3
Maintain the Pet TurboEraser® Tool
1
Twist gray collar counter-
clockwise, until slot appears,
and then separate faceplate.
3
Unplug and
turn vacuum
over. Unscrew
7 Phillips head
screws to
remove cover.
Inspect brush roll
by placing it on its
end and spin. The
brush roll should
spin freely, multiple
times by one flick.
If it doesn't, replace
brush roll. Inspect
belt, replace if
damaged.
To reassemble, align
two clips on each end
of paddle wheel with
belt on and pop back
into place.
Replace brush roll
with belt, making sure
all parts are aligned
correctly.
2
Pull roller straight out and slide belt off
motor gear. Replace roller and/or belt.
4
Pinching belt around brush roll and
hook back around the motor gear.
Rotate brush roll into place and line
up end caps to reinsert into vacuum.
Re-attach bottom cover with 7 screws.
Paddle Wheel
2
Belt
Roller
4
Remove brush roll,
belt, and paddle
wheel. Inspect
for damages and
replace if necessary.
To put faceplate
back on, align the
tabs in the top of
the cover and place
it down to "click"
into place.
www.BISSELL.com