Installation And Lubrication; Parts And Maintenance - Ingersoll Rand 2151RAC Serie Especificaciones Del Producto

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

Installation and Lubrication

Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air fi lter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-off , to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 04581666 and table on page 2.
Maintenance frequency is shown in a circular arrow and defi ned as h=hours, d=days, and
m=months of actual use. Items identifi ed as:
1.
Air fi lter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve
5.
Hose diameter
6.
Thread size

Parts and Maintenance

When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Offi ce or Distributor.
EN-2
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Grease - during assembly
11. Grease - through fi tting
04578811_ed3

Publicidad

Tabla de contenido
loading

Tabla de contenido