This appliance is filled with a precise quantity of oil.
Any reparations requiring the opening of the oil tank must be carried out only by the manufacturer
or its technicians, that should be contacted in case of oil leaks; when the appliance is scrapped, it is
necessary to comply with regulations concerning the disposal of oil.
2. ELECTRICAL CONNECTIONS
IMPORTANT
During installation, maintenance and cleaning, the appliance must not be powered.
The appliance must be powered only with 230 Vac voltage.
Depending on the version, the radiator is supplied with or without plug. In case of models without
plug, the radiator has 3 cables as per the table below:
For radiator models supplied without plug, the power cable must be absolutely connected to power
supply through a junction box positioned at 25 cm from the floor and without using any power plug.
WARNING
The Pilot Wire is intended for radiators sold in France.
If the black "pilot wire" is not used, safety standards impose to insulate it and not to connect
it for any reason to the ground wire.
It is compulsory to install a multipolar switching device. The minimum separation distance between
contacts shall be at least 3 mm.
It is compulsory that the power supply circuit of the appliance is protected by a high sensitivity
differential protection device.
Do not introduce and do not try to penetrate with metal objects into the side of the radiator
containing the adjustment electrical system (right side).
If the power cable is damaged, it must be replaced only by a qualified electrician.
2.1. DETAILS ON INSTALLATION IN THE BATHROOM
Installation must be compliant with the standards and laws in force in the country of installation.
The radiator is in class II and with IP24 electrical protection. In the bathroom, it can be installed in
areas 2 and 3 (see figure no.1) only if the control device cannot be touched by people that are using
the shower or the bath.
In the case the radiator power supply cable is supplied without plug, it mustn't be connected to
the earth wire.
22
Brown
Phase
Blue or Grey
Neutral
Black
Pilot wire
EN