Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
3.
Poor spray
pattern.
4.
Circuit board LED
is not lit.
5.
Water drip or
trickle when
faucet is not in
use.
Kohler Co.
Probable Causes
Recommended Action
C. The hot
C. Confirm the supply
and/or cold
hoses are not kinked or
supply hose
twisted. If coiled,
is kinked or
maintain an inside
twisted.
diameter of 3" (76 mm).
D. The outlet
D. Confirm the solenoid
hose is
valve is located within
kinked.
7" (178 mm) to 8" (203
mm) from the faucet
base.
E. Refer to the "Cleaning
E. One or more
screens are
the Screens" section.
clogged.
F.
Cracked
F.
Replace the solenoid
diaphragm.
valve assembly.
A. The spray
A. Rub your finger over
nozzles are
the nozzles with water
clogged.
running to dislodge
debris.
A. No power to
A. Check the power
the circuit
supply connections to
board.
the circuit board.
B. Power cord is
B. Plug the power cord
plugged into
into an unswitched 120
a switched
VAC outlet (test the
outlet.
outlet with a radio or
other device). Confirm
the circuit board LED
illuminates.
A. Manual
A. Turn the white manual
override is
override clockwise until
partially
it stops; then turn it
engaged.
counterclockwise until
the water drip stops.
17