Perel AOBD2 Manual Del Usuario página 6

Lector de códigos universal obd-ii/eobd y can
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
If the codes are not successfully cleared, ERASE FAIL will be displayed. Press ENTER to return to the main
menu.
6.3
Retrieving I/M Readiness Status
The I/M Readiness function is used to check the operations of the emission
system on OBD-II-compliant vehicles. It is an excellent function to use prior to
having a vehicle inspected for compliance to a state emissions programme. A
negative test result does not necessarily indicate that the tested vehicle will fail
YES: All supported monitors on the vehicle have completed their diagnostic
testing and the MIL light is on.
NO: At least one monitor supported on the vehicle has not completed its
diagnostic testing and/or the MIL light is on.
READY: Indicates that a particular monitor being checked has completed its
diagnostic testing.
NOT RDY: Indicates that a particular monitor being checked has not completed
its diagnostic testing.
N/A: The monitor is not supported on that vehicle.
: A flashing right arrow indicates additional information is available on the next
screen.
: A flashing left arrow indicates additional information is available on the
previous screen.
1. Select the I/M function by pressing ENTER.
2. Use SCROLL to view the status of the MIL light and the monitors:
MISFIRE: Misfire monitor.
FUEL: Fuel system monitor.
CCM: Comprehensive components monitor.
EGR: EGR system monitor.
O2S: O2 sensors monitor.
AT: Catalyst monitor.
V. 01 – 07/02/2017
AOBD2
IMPORTANT
the state I/M inspection.
6
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido