10 Technical Data
10.1 General data
Power supply
Max. power consumption
Intermittent (periodic
operation)
Type of protection, entire
device
Length of power cord
Battery type remote control 2 x AA (LR6) / 1.5 V
Type water supply
connection
Ø Connection at shower
toilet
Ø T-piece
Ø Connection hose
Length connection hose
Water supply pressure
Water supply temperature
Operating temperature
Product width
Product length
1590625-D
220 – 240 V AC, 50/60 Hz
1725 – 2053 W
85%, 30 min. ON / 5 min.
OFF
IPX4
1)
1.4 m
Direct connection to the
water supply
1/2"
1/2"- 3/8" - 1/2"
1/2" cranked to 3/8"
500 mm
79 – 735 kPa
3 – 25 °C
3 – 40 °C
389 mm
515 mm
Product depth
Product weight
Cleansing functions
Water flow rate CLEANSING
Water flow rate BIDET
Water pressure adjustment
Temperature adjustment
Heater capacity
Safety devices
Warm seat
Temperature adjustment
Heater capacity
Safety devices
Drying functions
Temperature adjustment
Heater capacity
Safety devices
1)
Protected against the penetration of water that is splashed
against the housing from all directions (warm seat only).
Technical Data
156 mm
3.9 kg
0.7 l/min
0.85 l/min
3 levels
Normal water supply
temperature,
34 °C, 37 °C, 40 °C
1670 – 1987 W
Thermal fuse, Thermostat
Room temperature, 35 °C,
38 °C, 40 °C
55 – 65 W
Thermal fuse
Room temperature – 50 °C
(5 levels)
195 – 232 W
Thermal fuse, Bi-metal
31