Declaration Of Conformity - Sagola RAIDER 300 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Failure
The Product is not sprayed
The unit builds up too much
pressure
There is product leak
through the packing gland
The air motor freezes too
much
The unit is leaking air and
produces a small number of
cycles when purging
In accordance with Directive 2006/42/EEC
Manufacturer:
Address:
Hereby declares that the product:
Brand:
Product line:
It is in accordance with the Essential Safety Requirements set out in the Annex to Directive 94/9/EEC.
For compliance with the requirements, the product complies with the standards:
- Directive of the EC Machinery (2006/42/EEC)
Also is in conformity with the provisions of the following Directives:
- ATEX regulation (Directive 94/9/EEC)
Marked "X" All static electricity is discharged by the air ducts.
Air hoses should be "ANTISTATIC"
Also is in conformity with the provisions of the following Directives: UNE-EN-13463-1:2011,
UNE-EN ISO 12100:2012, EN 809, EN12621, EN12162 and EN 1127-1.
The complete technical documentation and service instructions for the product are available.
In Vitoria-Gasteiz, on 01/07/2017
Cause of the failure
The product Filter is blocked
The Aircap is blocked
The purge valve is open or faulty
The anti-pulsation Filter is blocked
Unit disconnected from the air supply, air valve
closed or air inlet pressure regulator closed
The Piston Valve is dirty or damaged
The pressure regulator is damaged
Excessive pressure at the air supply
There is a fault in the hydraulic circuit
Damaged gaskets or damaged Piston Shaft
Use of the unit at higher pressures than is
admissible
Untreated compressed air
The air Compressor generates too much
humidity in the compressed air
Insufficient air supplied. Inadequate air hose
(small Ø or air inlet regulator not adjusted (set
at zero)
Gaskets in poor condition
Pneumatic distributor damaged

20. DECLARATION OF CONFORMITY

SAGOLA S.A.
C/ Urartea, 6 · 01010 VITORIA-GASTEIZ (Álava) · SPAIN
SAGOLA
RAIDER 300
II 2G, IIB T3 X.
Repair
Clean it or Replace it
Clean it and/or Replace it
Close it or replace it
Clean it or Replace it
Connect the unit to the supply. Open the
air valve or adjust the pressure regulator
to allow air to flow.
Clean it and/or Replace it
Replace it
Do
recommended work pressures
Send the unit to the S.A.T. SAGOLA
Replace the gaskets and/or the Piston
Shaft
Check that the air inlet pressure regulator
operates correctly
Install air filtering group
Purge the air Pressure Pot
Replace the air hose. Adjust the pressure
Regulator and increase the pressure.
Replace them
Replace it
Signed: Technical manager
Enrique Sánchez Uriondo
- 23 -
not
exceed
the
maximum

Publicidad

Tabla de contenido
loading

Tabla de contenido