Troubleshooting

Issue
Reason
No Water Flow
Water not connected
Water valve has malfunctioned
Outlet is blocked
Water pressure in excess of
70PSI (5 bar)
Unit will not
Unit has lock on feature in use
shut-off
Water valve has malfunctioned
No chemical
Low water pressure
suction
Tube kink
Chemical container empty
Blocked foot valve
Blocked dilution valve
Loose dilution valve (open
atmosphere)
Flood ring in outlet has moved
Too much
Dilution pin on wrong setting
chemical
Chemical is stiffening
Licence No. WMK25899
Specification: ATS5200.101 - 2005
Solution
Check water connection
Replace valve
Unblock or replace part
Fit water regulator to mains supply
Push the operating button to deactivate
Replace the water valve
Minimum 30PSI running water (2 bar)
Re-route tube
Replenish chemical
Clean or replace valve
Remove and clean part
Check dilution clamp
Replace outlet tube assembly
Change ratio
Lower chemical below unit injection point