TB 30 AM DRAWER
The fuse blows.
The compressor is
operating intermittently.
The compressor never
stops (correct fridge
performance)
The compressor never
stops (poor fridge
performance)
For more complicated defects requiring specialised assistance, please contact Indel B S.r.l. Italia
or your nearest TB 30 AM DRAWER retailer.
TB30AM DRAWER_20-06-2018
The wrong fuse is being
used. Defective electronic
control unit.
Battery low or electrical
cables in poor conditions.
Incorrect thermostat
connection on the electronic
control unit. Thermostat
broken. Condensation
is not working properly,
evaporator cools but not
enough to cause the
thermostat to stop the
compressor.
Environment very hot +
insufficient ventilation or
little gas in the refrigerant
circuit.
Check the fuse: see table in section
4.4. Replace the electronic control unit.
Check wiring conditions, examining for
loose connections, rust or verdigris. If
wiring needs to be replaced, see the
manual for correct sizing. If wiring is in
good conditions, check battery function
and replace if in poor condition.
Rotate the thermostat to off position. If
the refrigerator continues to function,
then there is continuity on the control
unit. Correct the problem on thermostat
connections (make sure the bridge
is present on C and P and not on C
and T on the electronic control unit).
Rotate the thermostat to off position.
If the compressor switches off but it is
impossible to regulate temperature,
replace the thermostat or recharge the
cooling system.
Check ventilation. The compressor
must be installed in a well-ventilated
location. If possible, remove the
refrigerator from the installation hole.
If the refrigerator operates better,
improve ventilation, consulting the
manual for correct installation. If
ventilation is instead optimal, check
for the presence of gas in the system,
contacting a specialised technician.