6 TROUBLESHOOTING
Disconnect the machine from the power supply prior to any checks performed at the
machine itself!
Fehler
Machine does not start
Saw band does not come to
full speed, no power
Motor gets hot very fast and
has weak performance
Saw band runs in opposite
direction
Machine vibrates
Bad cuts
MANY MALFUNCTIONS AND DEFECTS CAN BE AVOIDED BY LETTING THE MACHINE BE
CONNECTED TO YOUR POWER SUPPLY BY A CERTIFIED ELECTRICIAN
6.1
Adjust saw frame
If you receive straight and clean cut-
ting surfaces but the cuts are not 90°,
it is very likely that your saw frame
became outbalanced. In this case you
have to readjust it.
You can readjust the saw frame by
turning part No° (32) that regulates
within a tolerance level the descent angle of the saw frame.
Mögliche Ursache
Machine not connected to pow-
er supply
Fuse of power circuit defect or
not suitable
Cable defect
To long extension cord
Power supply not matching with
motor requirements.
Weak, instable/volatile power
supply
Motor does not receive power
on one or even 2 phases
2 of the 3 leading phases are
switched whether in Plug or
socket
Placed on uneven underground
Motor or any other parts loose
too high descent velocity
unsuitable saw band for cutted
material
worn saw band
saw band not tensioned
correctly
saw band guide outbalanced
saw frame outbalanced
Behebung
Check all power connections
Change fuse
Change cable
change to suitable extension
cord with sufficient cross-
section, insulation and length
Let check by electrician
Contact electric power
company
Shut off machine immediate-
ly. Let the connection to
supply circuit be checked by
an electrician!
Shut off machine immediate-
ly. Let the connection to
supply circuit be corrected by
an electrician!
modify
check all screw joints if tigh-
tened
Reduce the descent velocity
Use e.g. for stainless steel HQ
Bi-Metal bands only
replace
tension saw band correctly
readjust saw band guide
see 6.1