Tabela De Los Rangos De Medición; Codificación Del Instrumento; Modelos Disponibles - COEL HW7000 Manual De Instrucciones

Controlador electronico digital microprocesado
Tabla de contenido

Publicidad

7.5 – TABELA DE LOS RANGOS DE MEDICIÓN
Entrada
tc J
"HCFG" = tc
- 256 ... 1832 °F
"SEnS" = J
tc K
"HCFG" = tc
- 454 ... 2498 °F
"SEnS" = CrAl
tc S
"HCFG" = tc
"SEnS" = S
tc B
"HCFG" = tc
"SEnS" = b
tc E
"HCFG" = tc
"SEnS" = E
tc L
"HCFG" = tc
"SEnS" = L
tc N
"HCFG" = tc
"SEnS" = n
tc R
"HCFG" = tc
"SEnS" = r
tc T
"HCFG" = tc
"SEnS" = t
tc C
"HCFG" = tc
"SEnS" = C
TECNOLOGIC IRS
range "A"
"HCFG" = tc
"SEnS"= Ir.J - Ir.CA
Pt100 (IEC)
"HCFG" = rtd
"SEnS" = Pt1
PTC (KTY81-121)
"HCFG" = rtd
"SEnS" = Ptc
NTC (103-AT2)
"HCFG" = rtd
"SEnS" = ntc
0..20 mA
"HCFG" = I
"SEnS" = 0.20
4..20 mA
"HCFG" = I
"SEnS" = 4.20
0 ... 50 mV
"HCFG" = UoLt
"SEnS" = 0.50
0 ... 60 mV
"HCFG" = UoLt
"SEnS" = 0.60
12 ... 60 mV
"HCFG" = UoLt
"SEnS" = 12.60
0 ... 5 V
"HCFG" = UoLt
"SEnS" = 0.5
1 ... 5 V
"HCFG" = UoLt
"SEnS" = 1.5
0 ... 10 V
"HCFG" = UoLt
"SEnS" = 0.10
2 ... 10 V
"HCFG" = UoLt
"SEnS" = 2.10
Potenciómetro
(> 1 KΩ)
"HCFG" = UoLt
"SEnS" = Pot
COEL
"dP" = 0
"dP" = 1, 2, 3
-160 ... 1000 °C
-160.0 ... 999.9 °C
-199.9 ... 999.9 °F
-270 ... 1370 °C
-199.9 ... 999.9 °C
-199.9 ... 999.9 °F
-50 ... 1760 °C
-50.0 ... 999.9 °C
-58 ... 3200 °F
-58.0 ... 999.9 °F
72 ... 1820 °C
72.0 ... 999.9 °C
162 ... 3308 °F
162.0 ... 999.9 °F
-150 ... 750 °C
-150.0 ... 999.9 °C
-252 ... 1382 °F
-199.9 ... 999.9 °F
-150 ... 900 °C
-150.0 ... 900.0 °C
-252 ... 1652 °F
-199.9 ... 999.9 °F
-270 ... 1300 °C
-199.9 ... 999.9 °C
-454 ... 2372 °F
-199.9 ... 999.9 °F
-50 ... 1760 °C
-50.0 ... 999.9 °C
-58 ... 3200 °F
-58.0 ... 999.9 °F
-270 ... 400 °C
-199.9 ... 400.0 °C
-454 ... 752 °F
-199.9 ... 752.0 °F
0 ... 2320 °C
0.0 ... 999.9 °C
32 ... 4208 °F
32.0 ... 999.9 °F
-46 ... 785 °C
-46.0 ... 785.0 °C
-50 ... 1445 °F
-50.8 ... 999.9 °F
-200 ... 850 °C
-99.9 ... 850.0 °C
-328 ... 1562 °F
-99.9 ... 999.9 °F
-55 ... 150 °C
-55.0 ... 150.0 °C
-67 ... 302 °F
-67.0 ...302.0 °F
-50 ... 110 °C
-50.0 ... 110.0 °C
-58 ... 230 °F
-58.0 ... 230.0 °F
-199.9 ... 999.9
-1999 ... 9999
-19.99 ... 99.99
-1.999 ... 9.999
Manual de instrucciones – HW7000
7.6 – CODIFICACIÓN DEL INSTRUMENTO
HW7000 a b c d e f g
a: ALIMENTACION
L = 24 VAC/VDC
H = 100...240 VAC
b: SALIDA OUT1
R = relé
C = Salida analógica 0/4...20 mA
- = no presiente
c: SALIDA OUT2
R = relé
- = no presente
d: SALIDA OUT3
R = relé
- = no presente
e: SALIDA OUT4
R = relé
- = no presente
f: interfaz de comunicación
I = interfaz serial RS 485 + entrada digital
- = no presente
g: salida de alimentación para el sensor
A = 12 VDC
B = 2,5 VDC (para entrada de potenciómetro)
Nota:
- La salida OUT4, si está presente, debe ser del mismo tipo de OUT3.
- La entrada digital solo puede estar presente como alternativa a la salida OUT4.

MODELOS DISPONIBLES:

HW7000 H _ _ _ _ _ A _
HW7000 H C R R _ I A _
HW7000 H C R R _ _ B _
HW7000 H R R _ _ _ A _
HW7000 H R R _ _ _ B _
HW7000 H R R R _ _ B _
HW7000 L R R _ _ _ B _
HW7000 H R R R _ I A _
HW7000 L _ _ _ _ _ A _
HW7000 L R R _ _ _ A _
HW7000 L R R R _ I A _
HW7000 L C R R _ _ A _
HW7000 L C R R _ I A _
8