Disconnect the machine from the power supply and ensure that power cannot be switched on again in error.
Remove the machine lid.
Remove the cover from the electrical panel on the back of the machine.
bl
br
gn
blue
brown
green
Table 1: Wire Colors
Warning!
Load and control wiring harnesses should be separated from one another in order to avoid noise in the control wiring
(electromagnetic compatibility).
Warning!
Lay any extra wiring in the opposite direction in order to avoid antenna-like behavior in the wires.
Secure relay K1/81 (Fig. 1, Pos. 1) and the relay holder to the existing holes in the machine chassis using two 4x10
screws.
Secure relay 2K1/73 (Fig. 1, Pos. 2) to the existing hole in the machine chassis using one 4x10 screw.
Feed wiring harness 55X-K1/81-K1/73-X3 to terminal block X3 (Fig. 1, Pos. 3) via the conduit in the machine chassis
(Fig. 1, Pos. 4).
Connect wiring harness 55X-K1/81-K1/73-X3 to the installed relay and to connection EZL 371
Connect wiring harness 55X-K1/81-K1/73-X3 to terminal block X3 (Fig. 1, Pos. 4). Observe the wiring diagram, wire
colors and the 5 imprinted on the brown wire; see Fig. 1, Pos. 4.
Secure the 55X-K1/81-K1/73-X3 wiring harness to the wiring harness near the main terminal block using the 200x4.8
cable tie.
Knock out the pre-cut hole for the external peak load cut-out module in the connection strip on the back of the
machine.
Secure the M20x1.5 screw for the external peak load cut-out module to the connection strip on the back of the
machine.
Connect the external peak load cut-out module (Fig. 1, Pos. 5) to terminal block X3 (Fig. 1, Pos. 4) following the
module manufacturer's instructions.
Warning!
If no external peak load cut-out module is connected to terminal block X3, use the brown wire to jumper pins 4 and 5.
Perform a test run.
Re-install the cover on the electrical panel on the back of the machine.
Re-install the machine lid.
Carry out appropriate electrical safety checks.
Reconnect the machine to the electrical supply.
Note
Check the release point for peak load in all programs.