Troubleshooting - Broil King 9202-54 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

PROBLEM
SMELL OF GAS
Leak detected at cylinder,
regulator or other connection.
Flames Beneath Control
Panel (Flashback Fire)
Flickering Burner Flame or
Low Temperatures on HIGH
Setting
Burner Not Lighting
Ignitor Not Working
Decreasing Heat, "Popping
Sound"
Regulator Humming Noise
Yellow Flame
If troubleshooting fails to solve any of these or any other issues, please visit www.omcbbq.com for more information including
troubleshooting videos, tricks and tips or call customer service at 1-800-265-2150
POSSIBLE CAUSE
SHUT OFF LP CYLINDER VALVE AT ONCE.
DO NOT USE THE APPLIANCE UNTIL LEAK IS SEALED.
1. Regulator fitting loose.
2. Gas leak in hose/regulator or control valves.
1. Venturi blocked.
1. Excess flow safety device has been
activated in connection between cylinder and
barbecue.
1. Out of LP Gas.
2. Ignitor issue.
3. Excess flow safety device has been activated.
4. Regulator is not fully connected to the cylinder
valve.
5. A leak in the system causing the excess flow
device to activate.
6. Venturi blocked or misaligned with valve
orifice.
7. Orifice(s) blocked.
8. Hose is twisted.
1. Ignitor wire(s) not connected
2. Electrode misaligned on burner
3. Ignitor malfunction
1. Out of LP Gas.
2. Venturi blocked.
1. Cylinder valve opened too quickly.
1. Some yellow flame is normal. If it is
excessive, the venturi may be blocked.
2. Burner ports blocked.
CORRECTIVE ACTION
1. Tighten fitting and "Leak Test." (Page 6).
2. See authorized service center.
1. Remove burner and clean venturi. See "Venturi
Tubes" (Page 7).
1. Turn LP cylinder valve off then turn all burners to
OFF position. Disconnect the regulator from the
cylinder. Wait two minutes. Re-attach regulator to
the cylinder. Open the cylinder valve slowly. Wait
one minute. Light grill as per "Lighting" (Page 8).
1. Refill LP Gas Cylinder.
2. Try manually lighting burner with a match. See
"Lighting" (Page 8). If burner lights successfully, it
is an ignitor issue. See "Ignitor not Working" below
3. Follow "Flickering Flame or Low Temperatures on
HIGH setting" solution above.
4. Tighten the regulator hand wheel.
5. Leak test connections to determine loose fitting.
Tighten fitting. Leak test system.
6. Remove burner, clean venturi and realign with
valve orifice. See page 7 for assistance.
7. Remove burner, clean orifices with a pin or fine
wire. Do not drill orifices.
8. Straighten hose. Keep away from bottom casting.
1. Ensure main burner and side burner electrode
wires are all connected
2. Realign electrode and clear any surrounding
debris from area
3. See "Lighting" procedure (Page 8).
1. Refill LP Gas Cylinder.
2. Remove burner, clean venturi. See "Venturi Tubes"
(Page 7) for assistance.
1. Open cylinder valve slowly.
1. Remove burner, clean venturi. See "Venturi Tubes"
(page 7) for assistance.
2. Remove burner & clean with soft bristle brush
(e.g. toothbrush).