4 von 26
No.
Mat. no.
Designation
3
Cable ties
1
Cable gland
1
Wiring diagram, MF07
1
Wiring diagram, PW 6107 - 6207, module 7
1
Wiring diagram, PW 8xx/4xx, MF07 - FRZ
Danger due to incorrectly carried out service and repair work
WARNING
Danger due to incorrectly carried out service and repair work
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
A
Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
A
All appropriate safety regulations must be taken into account.
A
First read the Technical Service Documentation (TSD), then commence work.
Risk of injury due to sharp edges
CAUTION
There may be a risk of injury due to sharp edges.
Risk of injury due to sharp edges!
A
Protective gloves should be worn and the edge protection, Mat. no. 05057680, should be used.
Installing flow meter FRZ01
PW6101, PW6131, PW6161, PW6201, PW6107, PW6137, PW6167, PW6207, PW413, PW418, PW811, PW814,
PW818
The flow meter can only be installed if the MF7 multifunction module is already installed and registered in the machine.
PW 6163, PW 6243, PW 6323
The flow meter can only be installed if the "BSF-RU flow meter clean/unclean side" kit is already installed in the
machine.
During installation, the adapter must be installed as a damper between the stopcock and the flow meter. Take note of
the arrow marked on the flow meter showing the correct direction of flow. Use the correct seals appropriate for the
pipe diameter only. In this way water can flow freely without added turbulence through the measuring area. Correct
flow measurement can only be achieved if these instructions are complied with.
A
Connect the flow meter to a 3/4" stopcock; see Fig. 1.
A
Connect the water intake hose or Y-piece to the flow meter; see Fig. 2.
Flow-meter connection for PW 6101, PW 6131, PW 6161, PW 6201
A
Remove the cover plate from the electrical connection on the rear of the machine; see the model-specific TSD.
A
Connect the flow-meter wiring in accordance with the "MF07" wiring diagram.
A
Reinstall the cover plate over the electrical connection on the rear of the machine.
Flow-meter connection for PW 6107, PW 6137, PW 6167, PW 6207
A
Remove the machine lid; see the model-specific TSD.
A
Punch out an appropriately sized opening for the cable feed-through on the upper rear panel.
07.06.2018
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 06258813