Check keyed plugs and swap if necessary:
Check keyed plug MFM 2-5, module 2 (liquid dispensing 7-12) EZL 230-A 42X for key 2-5 ; see the wiring diagram.
See Fig. 5, Pos. 3.
Register module 2 liquid dispensing 7-12 clean-soiled side:
Service mode
Main menu
button
Diskette symbol to save registration.
Switch on dispensing display.
Service mode
Main menu
Back button (go back one level)
Note
Through the switched-on dispensing display the user can select/deselect dispensing. When the display is switched
off, the user can only view if dispensing is on for the current program and how much is dispensed.
Switch the machine off to exit service mode.
Connect dispensing pumps as per wiring diagram and calibrate:
If the flow rate of the dispensing pumps is known, enter this value directly in programming mode (e.g., dispensing
pump 7).
Programming mode
button
Back button (go back one level)
If the flow rate of the dispensing pumps is not known, calibrate the dispensing pumps in programming mode
(e.g., dispensing pump 7).
Programming mode
Insert the dispensing pump intake hose into a container with a fill mark.
Fill the container to the fill mark.
Press the 0/1 button (dispensing pump runs for 60 seconds).
Use a beaker to refill the container to the fill mark.
Check the dispensed amount in the beaker and record in the display (V:.....mL).
Diskette symbol to save the dispensed amount.
Register an empty status message (e.g., dispensing pump 7).
Programming mode
OK button
Back button (go back one level)
Check dispensing in each program and adjust settings as necessary.
Perform a function check.
Back up data via service mode.
Service mode
Main menu
overwrite EW data.
Switch off the machine to exit service mode.
Finish up:
Check all water connections for leaks.
Re-install the chassis lid, the lid on the water side, the liquid dispensing cover and the connection box cover.
Perform an electrical safety check.
am
09.06.2010
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Service settings
Module registration
Service settings
Basic settings
Diskette symbol to save.
Main menu
Settings
Dispensing flow rate
Diskette symbol to save flow rate.
Main menu
Settings
Calibrate dispensing
Main menu
Settings
Empty message for dispensing
Diskette symbol to save empty message.
Backup
Backup data for EW
Umbau- und Montageanweisung
EZL with coding 2
Dispensing
Dispensing: No
Dispensing pump 7: No
Dispensing pump 7
Dispensing pump 7: No
Overwrite existing data?
Diskette symbol to
M.-Nr. 07523811
Register module?
OK
Yes
OK button
.....mL/min
OK
Yes