Electrical Features - Manusa Visio Manual De Instrucciones

Ocultar thumbs Ver también para Visio:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DUSI01EN - v5
1 - MACHINE IDENTIFICATION
1.1– INTRODUCTION
manusa
All
automatic doors have been designed to ease a quick, safe and controlled access for pedestrians to all type of
installations.
The VISIO operator has been designed paying special attention to the design:
- low visual impact thanks to its reduced dimensions.
- improved integration with other architectural elements.
- possibility to operate the door using the user-friendly SMART program switch, which incorporates a large LCD screen.
This manual contains all basic instructions for the correct use of the automatic door. Please read it with special attention, and
in case of doubts or questions, please call an authorized technical service.
For your own safety, please observe the technical instructions described in this manual.
sability for damages or break-downs caused by non observing instructions herein.
We thank you for your confidence in
installation of automatic doors.
Outside detector
Inside detector
Outside push-button
Inside push-button
Outside key switch
Sliding leaf
Fixed leaf
1.2– TECHNICAL FEATURES
Height of the operator
Max. Clear Width - single slide door
Max. Clear Width - bi-part door
Max. leaf weight - single slide door
Max. leaf weight - bi-part slide door
PERFORMANCE
Adjustable opening speed - bi-part door
Adjustable opening speed per leaf
Adjustable closing speed per leaf
Adjustable closing force
Max. Acceleration
Independent adjustment of force and speed
manusa
, a company with more tan 40 years of experience in the design, production and
DIMENSIONS
125mm (175 opt)
2000mm
2950mm
1 x 160kg
2 x 120kg
80 a 200 cm/s
40 a 100 cm/s
15 a 60 cm/s
40N a 140N
2 m/s
2
Yes
AUTOMATIC DOOR WITH VISIO OPERATOR - USER MANUAL
Clear width

ELECTRICAL FEATURES

Standard power supply
Motor
Inverter technology
Maximum operating power
Temperature of operation
Obstruction detection with automatic reopening
Fail-safe batteries. Emergency opening on power failure.
Safety photocell barriers / Self-monitored.
15
manusa
does not hold any respon-
Operator
Program switch
Fixed leaf
Photocell barrier
Sliding leaf
230 Vac 50Hz
(115V under request)
2 AC three phase brush-
less motors with direct
drive technology
VV-VF
265W
-15ºC to 50ºC
SAFETY
Yes
Yes
Max 3