4.4– PROCEDURE IN THE EVENT OF A POWER FAILURE.
DOOR WITHOUT LOCK
- After a power failure, the door will open or close automatically using batteries according to the settings programmed by the
Technical Service*, except when the power failure occurs in CLOSED mode, in which case the door will remain closed.
- During power failure: the door can be opened or closed by hand.
- When the power is restored, the door will work in the most recent operating mode selected.
DOOR WITH LOCK
- After a power failure, the door will open or close automatically using the batteries, according to the settings programmed by
the Technical Service*, except when the power failure occurs in CLOSED mode, in which case the door will remain
closed.
- During power failure: the door can be opened or closed by hand. In addition, the door leaves can be locked or unlocked by
activating the lock using the manual release switch or the exterior key switch (optional). To do so, take the following
steps:
Open door
1.– Activate the lock release switch (1.a), or actívate the
exterior key (1.b*).
1
1.a
2.– Open the door by separating the door leaves by hand.
2
To open the door from the outside without power supply,
simply move the door leaves by hand to open position.
* Default configuration is to open, in order to facilitate evacuation in the event of power failure.
(optional)
1.b*
22
AUTOMATIC DOOR WITH VISIO OPERATOR - USER MANUAL
Close door
1.– Close the door by joining the door leaves by hand.
1
2.– Activate the lock release switch (2.a), or actívate the
exterior key switch (2.b*).
2
1.a
When the power is restored, the door will detect whether the lock
is blocking the door leaves::
- If the lock is blocking the door leaves, the door
changes to close mode, regardless of the
Operating mode of the door prior to power failure.
- If the lock is not blocking the door leaves, the door will
resumen operation with last operating mode
selected.
1.b*
(optional)