Machine Information - VONROC CD503DC Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
EN
ADDITIONAL SAFETY WARNINGS FOR DRILLS
AND SCREW DRIVERS
a) Wear ear protectors when impact drilling.
Exposure to noise can cause hearing loss.
b) Use auxiliary handle(s), if supplied with the
tool. Loss of control can cause personal injury.
c) Hold power tool by insulated gripping surfaces,
when performing an operation where the cut-
ting accessory may contact hidden wiring or its
own cord. Cutting accessory contacting a "live"
wire may make exposed metal parts of the
power tool "live" and could give the operator an
electric shock."
d) Hold the machine with a firm grip. High
reaction torque can briefly occur while driving
in and loosening screws.
e) Secure the workpiece. A workpiece clamped
with clamping devices or in a vice is held more
secure than by hand.
f) Always wait until the machine has come to
a complete stop before placing it down. The
tool insert can jam and lead to loss of control
over the power tool.
g) Before any work on the machine (e. g.,
maintenance, tool change, etc.) as well as
during transport and storage, set the
direction switch to the middle position.
Unintentional actuation of the On/Off switch
can lead to injuries.
FOR THE CHARGER
Intended use
Charge only 4V max.1.5Ah Li-ion type recharge able
battery packs. Other types of batteries may burst
causing personal injury and damage.
a) The appliance is not to be used by persons (in-
cluding children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given super-
vision or instruction
b) Children being supervised not to play with the
appliance
c) Do not recharge non-rechargeable batteries!
d) During charging, batteries must be placed in a
well ventilated area!
e) Integrated batteries may only be removed for
disposal by qualified personnel. Opening the
housing shell can destroy the power tool. To
remove the battery from the power tool, press
the On/Off switch (6) until the battery is fully
discharged. Unscrew the screws on the housing
and remove the housing shell in order to remove
6
the battery. To prevent a short circuit, disconnect
the connectors on the battery one at a time and
then isolate the poles. Even when fully dischar-
ged, the battery still contains a residual capacity,
which can be released in case of a short circuit.
RESIDUAL RISKS
Even when the power tool is used as prescribed it
is not possible to eliminate all residual risk factors.
The following hazards may arise in connection with
the power tool's construction and design:
a) Health defects resulting from vibration emission
if the power tool is being used over longer
period of time or not adequately managed and
properly maintained.
b) Injuries and damage to property to due to bro-
ken accessories that are suddenly dashed.
Warning! This power tool produces an
electromagnetic field during operation. This
field may under some circumstances
interfere with active or passive medical
implants. To reduce the risk of serious or
fatal injury, we recommend persons with
medical implants to consult their physician
and the medical implant manufacturer
before operating this power tool.

2. MACHINE INFORMATION

Intended use
This screw driver is intended for driving in and
loosening screws
TECHNICAL SPECIFICATIONS
Model No.
Charger
Input of charger
Output of charger
Rechargeable Battery pack
Battery charging time
Chuck capacity
No load speed
Sound pressure level L
PA
Sound power level L
WA
Hand-arm vibration a
h
(screw driving without impact)
CD503DC
CD810AA
100-240V~ 50/60Hz
0.3A
5.5V DC 0.7A
4V Li-ion 1.5Ah
2-3 hours
¼" (6.35mm) hex
200 /min
66.2 dB(A) K= 3 dB(A)
77.2 dB(A) K= 3 dB(A)
0.8 m/s
K=1.5 m/s
2
2
WWW.VONROC.COM

Publicidad

Tabla de contenido
loading

Tabla de contenido