6.
PUMP MAINTENANCE
WARNING!
Cleaning and servicing work must only be carried out after the operations described
in the chapter "HOW TO STOP THE PUMP" have terminated, i.e. none of the pipes
must be full of liquid on pressure.
6.1 Routine maintenance
Carry out the Operations described in the section "HOW TO STOP THE PUMP" and
comply with the instructions in the chart below.
SERVICING FREQUENCY
Whenever the pump is used
After every 50 hours service
6.2 Extraordinary maintenance
WARNING!
Used oil must be disposed of in an adequate way and not discarded in the
environment.
Comply with the extraordinary maintenance operations described in the chart below.
SERVICING FREQUENCY
After every 500 hours service or at the
end of each season
OPERATION
Check the condition and level of the
oil
Check the suction filter and clean it if
necessary
Check the inflation pressure of the
accumulator
Make sure that the suction circuit is in
a perfect condition
OPERATION
Replace the check valves
Replace the diaphragms
Change the oil
80