Maintenance; Possible Faults; Electrical Diagram - Haverland RC 4 ECO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

How to calibrate the heater temperature:
Assuming that the heater is set to Automatic and the display shows a room
temperature of 23 ºC:
Press the "OK" key for at least two seconds to access the functions
menu.
All the heater functions will be displayed on the upper section of the screen.
Use the
keys to position the function selector cursor
"Presence Sensor" (Note 11).
Note 11
Press "OK" to accept the "Presence Sensor" mode.
Press the
key. The "OFF-SET" operating mode will be displayed,
with the "C" of the degrees flashing:
Since the room temperature is 21.8 ºC, press the "-" key to change the
23 ºC to 21.8ºC. Each time you press the "+ / -", the room temperature will be
modified by 0.1ºC. Press the "-" key until the value 21.8 ºC is displayed on the
screen.
Once the temperature has been set, press the "OK" key and the screen will
display:
Press the "OK" key for at least two seconds to access the functions
menu. All the heater functions will be displayed on the upper section of the scre-
en.
Use the
the desired operating mode.
10º
By following the above steps you have now calibrated the Eco-Sensor
heater to the room temperature.
IMPORTANT NOTE:
Remember that the room temperature calibration adjustments are
maintained indefinitely until you decide to modify it again.
over the

13. MAINTENANCE

Your thermal transmitter does not require any special maintenance. It is only
necessary to remove the dust with a soft, dry cloth.
NEVER USE SOLVENTS OR ABRASIVE PRODUCTS.
It is recommended that the heater surface be cleaned when the heating sea-
son begins.

14. POSSIBLE FAULTS

1.- THE HEATER DOES NOT PRODUCE ANY HEAT.
Check that the thermal transmitter is not covered and that the air inlets are
not obstructed. The safety device will have tripped if the appliance has been
covered.
IN ORDER TO REST IT THE MAINS PLUG MUST BE REMOVED FROM
THE SOCKET FOR SOME FOUR MINUTES AND THEN PLUGGED IN
AGAIN.
2.- THE SENSOR DOES NOT DETECT.
Check that the sensor is not covered and that it is correctly located within the
room (page 37).
DO NOT INTERFERE WITH THE PRESENCE SENSOR. YOU COULD
DAMAGE IT.
3.- THE HEATER DOES NOT PROVIDE SUFFICIENT HEAT.
Check that the unit installed in the room has sufficient power.
IMPORTANT NOTE:
It is not recommended that the heater be switched off during normal
operation, because the room temperature must not be allowed to drop
too much.
For this reason, divide the 24 hours of each day into Comfort hours
(the time you will spend in the room) and Economic hours (the time
you will not be in the room).
Both temperatures should be adjusted in a reasonable, for example, a
Comfort temperature of 22 ºC and an Economic temperature of 17 ºC.
We sincerely hope that the Eco-Sensor heater will satisfy all your requi-
rements.
15. ELECTRICAL DIAGRAM RC-ECO
TE: ChronoThermostat ECO
TS: Safety Thermostat
PAG. 47
keys to position the function selector cursor
B: Connections diagram
RC: Resistance
over

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rc 6 ecoRc 8 ecoRc 10 ecoRc 12 eco

Tabla de contenido