C
ONTENTS OF THE ACCESSORIES BOX
Quantity
1
AC outlet
See notes
CONN. MC4 M 2.5-6mm2 MOVABLE
See notes
CONN. MC4 F 2.5-6mm2 MOVABLE
3 (1.5 kW/ 6 kW)
5 (10 kW/ 12.5
Ferrules for AC connections
kW)
1
Lug M4/6 mm
4 Ø6 mm screws and plugs for bracket mounting
(single phase models)
4/5
5 Ø10 mm screws and plugs for bracket mounting
(three phase models)
5
2.54 mm pitch jumper
2
M5x20 fixing screws for inverter brackets
2
M5 fixing nuts for inverter brackets
1
This manual
1
USB cable
2
MULTIHOLE M20 GASKET
1
Multihole m25 gasket
1
6 mm hole closing cylinder
2
5 mm hole closing cylinder
M
ECHANICAL INSTALLATION
See the instructions for mechanical installation included in the box
AC
CABLE CONNECTION CROSS SECTION
Size
1.5 kW
Maximum output
current (A)
Recommended
minimum cross
section (mm ²)*
Maximum cross
section permitted by
the connection
system.
* In the presence of long connecting lines (> 5m), we recommend using the maximum permissible section. If even larger cross
sections are needed (e.g. connections with length > 20 m), it is advisable to place the circuit breaker upstream in proximity of the
inverter and use the cross sections in the table for the first connection stretch only.
Description
2
C
2 kW
3 kW
7.5
10
1.5
1.5
4.0
4.0
In models where included.
DC connectors are provided in a number equal to the "Number of
pairs of DC connectors"
DC connectors are provided in a number equal to the "Number of
pairs of DC connectors"
2
4 mm
(6 mm2 in single phase models with more than one MPPT
tracker)
For connecting additional ground
For setting RS485 functions
For RS485 bus and alarm relay wiring
For the slot for communication boards
For the communication slot multihole gasket
For the communication drawer multihole gaskets
4 kW
15
20
2.5
2.5
4.0
4.0
10 with
ferrule
16 bare
copper
- 43 -
Remarks
5 kW
6 kW
25
30
4.0
4.0
10 with
ferrule
16 bare
copper
10 kW
12.5 kW
17
21
2.5
4.0
6.0
6.0