the lower field reduces the target temperature. The setting is saved if
no change occurs on the control panel for selection of temperature for
three seconds. The current room temperature is subsequently shown
on the display.
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the dis-
play. The ventilator remains switched on at the lowest level in order to
monitor room temperature. The appliance switches on again if the room
temperature recorded drops below the set target temperature.
5. Cooling mode: the heating element switches off if the temperature is set
to 32 °F / 0 °C and the ventilator blows cool air out of the appliance. The
LED light (7) changes from red to blue. There is no temperature shown
on the display in cooling mode.
6. The heat output level can be changed from low to high by making a
vertical sliding movement across the left-hand control panel for selec-
tion of heat output level (9) «Power Level». The display flashes during
the input process. Making a sliding movement upwards or typing «+» in
the upper field increases the output level. Making a sliding movement
downwards or typing «–» in the lower field reduces the output level. The
setting is saved if no change occurs on the control panel for selection
of heat output level for three seconds. The current room temperature is
subsequently shown on the display.
7. Auto mode is activated by pressing the «Auto Mode» button (10). «Auto
Mode» is shown in the display. The preset target temperature of 72 °F /
22 °C can be changed using the right-hand control panel for selection of
temperature (8). The heat output level is selected automatically in auto
mode - depending on the room temperature. The smaller the difference
between the room temperature and the target temperature, the smaller
the heat output level selected. We refer to this as «Adaptive Heat
technology and we have filed for an international patent. This allows
Paul to make sure that the target temperature is reached, quickly and
efficiently, and maintained. Paul thus prevents a sharp temperature drop
and prevents the appliance from being constantly switched on and off.
Auto mode is deactivated if the heat output level is changed manually
(9).
Info: The appliance switches off the heating element when the target
temperature is reached and the temperature indicator flashes on the
display.
8. The swing function can be activated by pressing one of the «Swing
Mode» buttons (11) on the left-hand and right-hand side of the hous-
ing. The appliance now swings at an angle of approx. 90 ° to ensure a
wide distribution of heat. Press the «Swing Mode» button again if the
appliance is to remain at a certain angle. If the target temperature is
reached, the appliance remains at the angle it was in at the point the tar-
get temperature was reached until the room temperature drops below
the target temperature and the appliance switches on again.
9. Switch off the appliance by pressing the On/Off button (6). The ventila-
tor remains switched on for three minutes at the lowest level to cool
down the heating element. The appliance saves the temperature input
and the heat output level even if the appliance is switched off.
10. The remote control (13) is in the compartment for remote control (12) on
the back of the appliance. The temperature and the heat output level
»
TM