Operation
Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode
3.Select temp.setting
Press
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed
changes as
follows:
Remote controller:
MED
LOW
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
Remote
Operation
Mode
Controller
13
button
Display
circulated
HI
AUTO
Note
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according
to room temperature.
In DRY mode , when room temperature becomes lower
o
than temp.setting+2
C, unit will run intermittently at LOW
speed regardless of FAN setting.
In HEAT mode, warm air will blow out after a short
period of the time due to cold - draft prevention function.
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
Timer
Designated
Fan
temperature
mode
temperature
speed
o
o
Above 23
C
26
C
AUTO
No
o
o
Below 23
C
23
C
No
AUTO
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
o
temperature is below 16
C, do not use it in the
normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice, release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Air Flow Direction Adjustment
1.Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
(Autoswing)
Pos.5
2.Press
button. changes as follows:
Press
button again , vertical flap will stop over
present position, the swing function will be cancelled
3.Press
button to choose the Pos.2 and Pos.3.
4.Left and right air flow adjustment(manual)
Move the vertical blade by a knob on airconditioner
to adjust left and right direction referring to Fig.
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller
controller will automatically memorize the previous set swing position.
Pi
Operation
mode
COOL
HEAT
Pi Pi
Remote controller
COOL/DRY/AUTO(Initial state):
HEAT(Initial state):
(no)
Pos.4
mode ,