Control Via Midi Software - IMG STAGELINE MFX-204 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44

8.2 Control via MIDI software

GB
1) Connect the jack MIDI INPUT (16) via a MIDI
cable to the MIDI output of the PC. The jack
MIDI OUTPUT (15) allows connection of
another MIDI-controlled unit.
2) For MIDI control, set the MFX-204 to the MIDI
channel used for controlling it:
a) Keep the button FX LOAD/ PAR / TAP
pressed for approx. 3 seconds until the
following text is displayed:
Config Communication
<
Device:
USB
If the MFX-204 has already been con-
trolled via MIDI, the last MIDI channel
adjusted will appear behind "Device", e. g.
<
"Device:
MIDI Ch=12
MIDI channel 12.
b) Select the MIDI channel (1 – 16) with the
control PAR VALUE (7). If the display indi-
<
cates "Device:
trol counter-clockwise.
c) To exit the setting mode, keep the button
FX LOAD/ PAR / TAP pressed again for
approx. 3 seconds until the display indi-
cates an effect name.
3) After setting the MIDI channel, the effects will
be selected with a corresponding Program
Change command. Control Change com-
mands are used to activate and deactivate the
Bypass function and to change all effect
parameters. The tables below list the values
required.
Activating effects
with Program Change command
Effect
Decimal value
REVERB HALL
0
REVERB ROOM
1
REVERB PLATE
2
REVERB VOCAL
3
GATE REVERB
4
VOCAL ECHO
5
TAP DELAY
6
CHORUS
7
FLANGE
8
PHASER
9
TREMOLO
10
ROTARY
11
CHR / FLG REVEB
12
DELAY REVERB
13
CHR / FLG DELAY
14
PITCH SHIFTER
15
Table 1
18
Changing parameters or activating the
Bypass function with Control Change
commands
Select parameter
Change value
>
Table 2
To change a parameter, send two Control
Change commands to the MFX-204:
>
" for control via
1) First select the parameter to be changed. For
this purpose, set MIDI controller 17 to the
value corresponding to the parameter num-
ber minus 1.
>
USB
", turn the con-
Example: For the effect REVERB HALL,
select the parameter PEQ1 Q (bandwidth of
bell filter 1): According to the table on page 3,
parameter PEQ1 Q is number 9. Therefore,
set MIDI controller 17 to the value 9 – 1 = 8.
2) To change the parameter, set MIDI controller
16 to a corresponding value. Tables 3 – 6 list
the values to be set:
1. All values for frequencies, gain or attenua-
2. Percentage values are implemented 1: 1,
Hexadecimal value
3. Parameters with a switching function are
00H
01H
4. The values of all parameters with a time
02H
03H
04H
05H
06H
07H
08H
09H
0AH
0BH
0CH
0DH
0EH
0FH
Function
MIDI controller
parameter number
17
(see page 3) minus 1
16
see tables 3 – 6
0 = off
Bypass
80
1 = on
tion, bandwidth and semitones are listed in
table 3. Example: If the desired bandwidth
of bell filter 1 (PEQ1 Q) is 1.5 octaves, set
MIDI controller 16 to the value 29.
see table 4. Example: To set the parame-
ter Decay to 65 %, set MIDI controller 16
to the value 65.
listed in table 5; they are changed by the
value 0 or 1.
unit can be found in table 6. Please note
that the step sizes will differ according to
the adjusting range.
Example: Setting the parameter Time of the
effect GATE REVERB to 100 ms: The next
possible value is 94.5 ms (3 × 31.5 ms). For
this purpose, set MIDI controller 16 to the
value 3.
Values for controller 16
Frequency
Gain
20 Hz
-15.0 dB
Value
25 Hz
-14.5 dB
31.5 Hz
-14.0 dB
40 Hz
-13.5 dB
50 Hz
-13.0 dB
63 Hz
-12.5 dB
80 Hz
-12.0 dB
100 Hz
-11.5 dB
125 Hz
-11.0 dB
160 Hz
-10.5 dB
200 Hz
-10.0 dB
250 Hz
-9.5 dB
315 Hz
-9.0 dB
400 Hz
-8.5 dB
500 Hz
-8.0 dB
630 Hz
-7.5 dB
800 Hz
-7.0 dB
1 kHz
-6.5 dB
1.25 kHz
-6.0 dB
1.6 kHz
-5.5 dB
2 kHz
-5.0 dB
2.5 kHz
-4.5 dB
3.15 kHz
-4.0 dB
4 kHz
-3.5 dB
5 kHz
-3.0 dB
6.3 kHz
-2.5 dB
8 kHz
-2.0 dB
10 kHz
-1.5 dB
12.5 kHz
-1.0 dB
16 kHz
-0.5 dB
20 kHz
0 dB
0.5 dB
1.0 dB
1.5 dB
2.0 dB
2.5 dB
3.0 dB
3.5 dB
4.0 dB
4.5 dB
5.0 dB
5.5 dB
6.0 dB
6.5 dB
7.0 dB
7.5 dB
8.0 dB
8.5 dB
9.0 dB
9.5 dB
10.0 dB
10.5 dB
11.0 dB
11.5 dB
12.0 dB
12.5 dB
13.0 dB
13.5 dB
14.0 dB
14.5 dB
15.0 dB
Table 3
Bandwidth
Semitones
Value
0.05 oct.
-12.00
0
0.10 oct.
-11.67
1
0.15 oct.
-11.33
2
0.20 oct.
-11.00
3
0.25 oct.
-10.67
4
0.30 oct.
-10.33
5
0.35 oct.
-10.00
6
0.40 oct.
-9.67
7
0.45 oct.
-9.33
8
0.50 oct.
-9.00
9
0.55 oct.
-8.67
10
0.60 oct.
-8.33
11
0.65 oct.
-8.00
12
0.70 oct.
-7.76
13
0.75 oct.
-7.33
14
0.80 oct.
-7.00
15
0.85 oct.
-6.67
16
0.90 oct.
-6.33
17
0.95 oct.
-6.00
18
1.00 oct.
-5.67
19
1.05 oct.
-5.33
20
1.10 oct.
-5.00
21
1.15 oct.
-4.67
22
1.20 oct.
-4.33
23
1.25 oct.
-4.00
24
1.30 oct.
-3.67
25
1.35 oct.
-3.33
26
1.40 oct.
-3.00
27
1.45 oct.
-2.67
28
1.50 oct.
-2.33
29
1.55 oct.
-2.00
30
1.60 oct.
-1.67
31
1.65 oct.
-1.33
32
1.70 oct.
-1.00
33
1.75 oct.
-0.67
34
1.80 oct.
-0.33
35
1.85 oct.
0
36
1.0 oct.
0.33
37
1.95 oct.
0.67
38
2.00 oct.
1.0
39
2.05 oct.
1.33
40
2.10 oct.
1.67
41
2.15 oct.
2.00
42
2.20 oct.
2.33
43
2.25 oct.
2.67
44
2.30 oct.
3.00
45
2.35 oct.
3.33
46
2.40 oct.
3.67
47
2.45 oct.
4.00
48
2.50 oct.
4.33
49
2.55 oct.
4.67
50
2.60 oct.
5.00
51
2.65 oct.
5.33
52
2.70 oct.
5.67
53
2.75 oct.
6.00
54
2.80 oct.
6.33
55
2.85 oct.
6.67
56
2.90 oct.
7.00
57
2.50 oct.
7.33
58
3.00 oct.
7.67
59
8.00
60
8.33
61
8.67
62
9.00
63
9.33
64
9.67
65
10.00
66
10.33
67
10.67
68
11.00
69
11.33
70
11.67
71
12.00
72

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

25.2650