Disposal - Hilti PX10 Manual De Instrucciones

Ocultar thumbs Ver también para PX10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Fault
The receiver is switched on but
no signal is indicated on the
display.
The transmitter cannot be
switched on or switches itself
off after a short time.
The receiver cannot be
switched on or switches itself
off after a short time.
Measurements are inaccurate.
The direction indicator arrows
flicker at random.
The adhesive putty doesn't hold
properly.

10 Disposal

CAUTION
Improper disposal of the equipment may have serious consequences: The burning of plastic components generates
toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high
temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit
unauthorized and improper use of the equipment. This may result in serious personal injury, injury to third parties and
pollution of the environment.
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The materials must
be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements for
taking back old tools and appliances for recycling. Ask Hilti customer service or your Hilti representative for further
information.
For EC countries only
Disposal of electric tools together with household waste is not permissible.
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment and its
implementation in accordance with national law, electric tools that have reached the end of their life
must be collected separately and returned to an environmentally compatible recycling facility.
Dispose of the batteries in accordance with national regulations.
Possible cause
The signal is screened by sheet
metal.
The battery is dead.
The battery is dead.
The influence exerted by metal is too
strong.
The tool is faulty.
Microphonia effect due to strong vi-
bration of the receiver.
Interference fields, e.g. caused by
cordless telephones, switched-on
computer screens etc.
The adhesive putty has been used too
often.
The contact surfaces are not clean.
Remedy
If possible, make the measurements
at an area where there is no sheet
metal.
Change the transmitter battery.
Change the receiver battery.
Check accuracy by making measure-
ments "in the air" or on a wall con-
taining no steel reinforcement.
Have the tool checked at a Hilti ser-
vice center if the measuring tolerance
is exceeded.
Keep the receiver steady.
Switch off the source of all interfer-
ence fields.
Use new adhesive putty.
Clean the contact surfaces.
en
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Px 10Px 10tPx 10rPxa 70

Tabla de contenido