Instructions for submersible pumps
When you purchase your pump the swivel
feet are set to the flat suction position
(1 mm).
v For normal operation, turn the feet 180°
to 5 mm.
The pump is lifted 5 mm.
v Clear the outlet line before use.
Thermal protection switch
The pump is automatically switched off on
overheating by the built-in thermal motor
protector. After having cooled down, the
motor automatically switches on again (see
7. Troubleshooting).

3. Initial Operation

Hose diameter
a
b
Hose connection
of universal fitting
Hose connection
Connecting the hose :
13 mm ( ¹⁄₂ " )
16 mm ( ⁵⁄₈ " )
19 mm ( ³⁄₄ " )
2
2
Cut off topmost
a
nipple at
The following connection kits are required for 13 mm to
19 mm connections:
13 mm ( ¹⁄₂ " ):
16 mm ( ⁵⁄₈ " ):
19 mm ( ³⁄₄ " ):
Best results in delivery capacity are achieved when using 38 mm
(1 ¹⁄₂ " ) hoses.
The universal fitting
in the previous table.
1. Cut off nipples of the universal fitting
to match the hose connection.
Automatic deaerating valve
If the pump is half submersed, water may
come out of the ventilation holes
This is not a defect of your pump, but serves
to deaerate the pump.
25 mm (1 " )
Do not cut off
.
any nipples.
GARDENA Pump Connection Set, Art. No. 1750
GARDENA Tap Connector, Art. No. (2)902,
and GARDENA Standard Hose Connector,
Art. No. (2)916
GARDENA Pump Connection Set, Art. No. 1752
2
allows you to connect all the hoses listed
The automatic
deaerating valve
eliminates any
air pockets in the
pump.
1
1
.
38 mm (1 ¹⁄₂ " )
Cut off top two
b
nipples at
.
2
, which are not needed,
13