Btl7 Configuration Tool; Connecting The Usb Communication Box; Configuration Options - Balluff BTL7-A501-M -A-S32 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL7-A501-M -A-S32 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-A/E501-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S140/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
6
Configuration with the BTL7 Configuration Tool
6.1

BTL7 Configuration Tool

NOTICE!
Interference in function
Configuration with the BTL7 Configuration Tool while the
system is running may result in malfunctions.
► Stop the system before configuration.
The BTL can be quickly and easily configured on the PC
using the PC software BTL7 Configuration Tool.
The most important features include:
Online display of the current position of the magnet
Graphical support for setting the functions and curves
Display of information on the connected BTL
Selectable number formats and units for display
Resetting to factory settings is possible
Demo mode without a connected BTL
The PC software and associated manual can
be found in the Internet under www.balluff.com.
6.2

Connecting the USB communication box

For a BTL with connector the communication box must be
inserted between the BTL and the controller. The
communication box is connected to the PC via a USB
cable.
USB cable
Connection cable approx. 0.3 m with
connector (socket)
Fig. 6-1:
Connecting the communication box with a connector
14
english
Connection cable
approx. 0.3 m with
connector (plug)
Controller
8-pin
6-pin
For a BTL with cable connection the communication lines
La, Lb and GND are connected to the USB communication
box.
USB cable
Fig. 6-2:
Connecting the communication box with a cable connec-
tion
When reading or writing data via the
Configuration Tool, both LEDs flash green.
6.3

Configuration options

Prerequisites
USB communication box connected to the BTL and
PC.
Software correctly installed.
BTL connected to the power supply.
Magnet on BTL.
Magnets and outputs
One or two magnets can be selected (factory setting:
one magnet)
Two outputs can be assigned independently
Output functions
Position: position in the measuring range.
Velocity: velocity of the magnet. The sign indicates the
direction of movement. Movement from the null point
to the end point is output with a positive sign.
Movement from the end point to the null point is output
with a negative sign. Max. detectable velocity range of
10 to +10 m/s.
Velocity (no sign): velocity of the magnet. The
direction of movement cannot be read. Max.
detectable velocity range of 0 to 10 m/s.
Differential position: Distance between two magnets.
Selection is only possible if two magnets have been
selected.
Controller
8-pin
Connection cable
approx. 0.6 m with
luster terminal

Publicidad