EINHELL TC-LD 50 Manual De Instrucciones Original página 21

Telemetro por laser
Ocultar thumbs Ver también para TC-LD 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the area width
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the first area
length
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the second
area length
→ The result is displayed at the bottom in m²
6.5.6 Function: "Indirect distance
measurement"
"Symbol
" (Fig. 10)
2 reference points (using the Pythagoras rule)
Procedure:
Press button B four times: Select function
Button F if necessary: Select the reference
point on the equipment
Caution!
The hypotenuse (1.) is measured fi rst, then
the adjacent side (2.), which must be at right-
angles to the required distance (opposite
side). The set reference point on the equip-
ment and the measuring position must be the
same when both points are set!
Press button A once: Switch on the laser
Align the laser
Button A once: Set the first point (hypotenu-
se) of the distance to be calculated
Press button A once: Switch on the laser
Align the laser
Button A once: Set the second point (adja-
cent side) of the distance to be calculated
→ The result is displayed at the bottom in m
6.5.7 Function: "Indirect distance
measurement
3 reference points (using the Pythagoras rule)"
"Symbol
" (Fig. 11)
Procedure:
Press button A once and keep it pressed for a
short time: Switch on the equipment
Press button B five times: Area measurement
function
Button F if necessary: Select the reference
point on the equipment
Anl_TC_LD_50_SPK9.indb 21
Anl_TC_LD_50_SPK9.indb 21
GB
Caution!
The hypotenuse (1.) is measured fi rst, then
the adjacent side (2.), which must be at right-
angles to the required distance (opposite
side).
The set reference point on the equipment and
the measuring position must be the same
when both points are set!
Press button A once: Switch on the laser
Align the laser
Button A twice: Set the first point (hypotenuse
1) of the distance to be calculated
Press button A once: Switch on the laser
Align the laser
Button A once: Set the second point (adja-
cent side) of the distance to be calculated
Press button A once: Switch on the laser
Align the laser
Button A once: Set the third point (hypotenu-
se 2) of the distance to be calculated
→ The result is displayed at the bottom in m
6.5.8 Function: "Staking out function
(min. 10 cm = 0.1m)"
"Symbol
" (Fig. 12)
Procedure:
Press button A once and keep it pressed for a
short time: Switch on the equipment
Press button B six times: Select function
Button F if necessary: Select the reference
point on the equipment
Button D (+): Select digit
Button E (-): Select size
Press button A once: Measurement
Move the equipment towards the back from
the reference point
→ Rapid beeping signals that the required
spacing has been reached
6.5.9 Function: "Add/subtract results"
"Symbol +/-" (Fig. 13)
Procedure:
Press button A once and keep it pressed for a
short time: Switch on the equipment
Button F : Select required function (distance,
area, volume)
Measure results (as described above)
Press button D (+) once: Add the new mea-
surement
Press button E (-) once: Subtract the new
- 21 -
12.11.2018 08:03:59
12.11.2018 08:03:59

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

22.700.80

Tabla de contenido