The maximum ambient temperature t
Operate the device only after having become familiar with its functions. Do not permit operation by persons
not qualified for operating the device. Most damages are the result of unprofessional operation!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
Never remove the serial barcode from the device as this would make the guarantee void.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamps
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 20 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need eight ENH 120 V/250 W GY-5.3 lamps.
During the operation, the lamp reaches temperatures of up to 375° C.
Caution! The lamps are extremely shock-sensitive!
Procedure:
Step 1: Unscrew the fixation-screw of the protective plate.
Step 2: Remove the protective plate.
Step 3: Unscrew the fixation-screws of the colour-filter holder.
Step 4: Remove the colour-filter holder.
Step 5: If replacing a lamp, remove the old lamp from the lamp-socket.
Step 6: Put the eight ENH 120 V/250 W GY-5,3 lamps into the respective lampholders.
Step 7: Put the first two lamp-sockets on the first two lamps.
Step 8: Put the remaining lamp-sockets on the respective pair of lamps (connected in series).
Step 9: Replace the colour-filter holder and tighten the screws.
Step 10: Replace the protective plate and tighten the screw.
Step 11: For transport, replace the protection-cover and tighten the screw.
= 45° C must never be exceeded.
a
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
14/33
00026772.DOC, Version 2.1