Minimum distance to reflective surfaces
WARNING
Failure to maintain minimum distances
to reflective surfaces may result in serious injury!
Determine the minimum distance (see figure
Make certain that all reflective surfaces are the necessary minimum distance
away from the protective field according to prEN IEC 61496-2 (see figure
).
3
Check that reflective surfaces do not impair the detection capability of the
safety sensor before start-up and at appropriate intervals.
2
a Required minimum distance to reflective surfaces [mm]
b Protective field width [m]
c Reflective surface
3
a Required minimum distance to reflective surfaces [mm]
b Protective field width [m]
Assembly
Mount the IP protective tube on the end caps.
To do this, use the mounting brackets included in the scope of delivery.
Tightening torque of the mounting screws: 3 Nm
Mount the transmitter or the receiver with the IP protective tube to the system
using the mounting brackets.
Electrically connect the transmitter or the receiver via the connection cable of the
IP protective tube.
Align the transmitter and receiver with one another – see chapter
ing
original operating instructions
in the
10
).
2
for the MLC.
Commission
-