User code entry mode (only applicable in multi-user mode)
Key-press acknowledge tones
Door open time-out
0
1 ~ 999
exit programming mode
information is saved and the keypad returns to normal working mode
Note: in case an error was made during programming, press the
or simply wait for 10s and try again.
9. Programming hints
single-user vs. multi-user mode
•
In single-user mode every output can be controlled by only one 4-digit
user code. User codes are stored in memory location
the
-confirmation is not required after entering the user code (auto-
entry mode).
•
In multi-user mode, up to 100 user codes can be assigned to control
output 1 and up to 10 to control output 2. These user codes can consist
of 4 to 8 digits and the
entering the code (manual entry mode). Before setting to auto-entry
mode, all user codes must have the same length as the master code
(between 4 and 8 digits).
Duress code
•
User code 1 in single-user mode and all user codes of group 1 in multi-
user mode come with a duress code function. This duress code is
v4 - 15.11.2013
notifying beep disabled and replaced by 2 short successful
code entry beeps for valid user codes
auto entry mode selected;
user code (user codes must have the same length as the
master code)(default for single-user mode)
manual entry mode selected;
user code (user codes length can differ from the master
code length) (default for multi-user mode)
key-press tones enabled (default)
key-press tones disabled
no door-open time-out (default)
alarm will be triggered when the door remains open
longer than the set time (1~999s)
-confirmation button must be pressed after
HAA2850
is not required after entering
12
is required after entering
and
. Default
button,
©Ve llema n nv