6. Operation
6.1 Using for the fi rst time
Install the equipment on a solid and level
surface.
Remove the ventilation screw (6).
Unscrew the coarse filter screw (4) using the
supplied wrench (10) and remove the coarse
filter (12) together with the non-return valve
(13) as shown in Figure 3. Now you can fill the
pump housing with water via the coarse filter
screw (4). Filling the intake line accelerates
the intake process.
Assemble in reverse order.
Open the discharge line.
Connect the mains cable.
Switch on the equipment with the power
switch (9) - water can be suctioned in for up
to 5 minutes (maximum suction height).
After finishing the work, switch off the equip-
ment with the power switch (9).
6.2 LED indicator and fl ow switch
Yellow LED is lit (Fig. 4 / Item B) - priming
operation:
To start the pump, press the power switch (9) and
the pump will start running straight away. When
the pump is started up, it starts up to 5 priming
attempts in a cycle of 60 seconds ON and 4 se-
conds OFF.
Green LED is lit (Fig. 4 / Item A) - normal
mode:
The pump is in normal mode and the fl ow switch
detects a waterfl ow. This means that water is
being pumped by the pump.
Yellow LED is lit (Fig. 4 / Item B) - normal
mode:
The pump is in normal mode and the fl ow switch
does not detect any waterfl ow.
Red LED is lit (Fig. 4 / Item C) - fault:
If the pump does not pump any water during the
priming attempt after the fi fth priming attempt, the
pump will switch off and the red LED will come on.
Disconnect the pump from the mains power sup-
ply and refi ll it and/or examine the intake line for
leaks. If, in normal mode, no water is pumped for
more than 5 minutes or no waterfl ow is detected,
e.g. if the spray nozzle is closed, the pump will
automatically switch to the dry-running protection
function and will switch off . The pump can be re-
Anl_GE_GP_1246_N_FS_SPK9.indb 18
Anl_GE_GP_1246_N_FS_SPK9.indb 18
GB
started again by pressing the power switch.
6.3 Intake pressure gauge
If the pump has been started up correctly, it will
pump water and the indicator on the intake pres-
sure gauge in the coarse fi lter screw (4) will rise
to the applicable suction height. During operation
the current suction height can be read off the in-
take pressure gauge (4). (Figure 5).
If the pump fails to pump any water when a pri-
ming attempt is made and the value on the intake
pressure gauge stagnates or stays at 0 m, this
means that there is a problem on the intake side.
Check all connections and the suction hose for
possible leaks. Filling the pump with water can
help the priming attempt. As a basic principle, we
recommend the use of a suction set with suction
hose, intake cage and non-return valve.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
There are no parts inside the equipment
which require additional maintenance.